aboutsummaryrefslogtreecommitdiff
path: root/tools/perf/pmu-events/arch/arm64/common-and-microarch.json
diff options
context:
space:
mode:
authorLibravatar Linus Torvalds <torvalds@linux-foundation.org>2023-02-21 18:24:12 -0800
committerLibravatar Linus Torvalds <torvalds@linux-foundation.org>2023-02-21 18:24:12 -0800
commit5b7c4cabbb65f5c469464da6c5f614cbd7f730f2 (patch)
treecc5c2d0a898769fd59549594fedb3ee6f84e59a0 /tools/perf/pmu-events/arch/arm64/common-and-microarch.json
downloadlinux-5b7c4cabbb65f5c469464da6c5f614cbd7f730f2.tar.gz
linux-5b7c4cabbb65f5c469464da6c5f614cbd7f730f2.zip
Merge tag 'net-next-6.3' of git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net-nextgrafted
Pull networking updates from Jakub Kicinski: "Core: - Add dedicated kmem_cache for typical/small skb->head, avoid having to access struct page at kfree time, and improve memory use. - Introduce sysctl to set default RPS configuration for new netdevs. - Define Netlink protocol specification format which can be used to describe messages used by each family and auto-generate parsers. Add tools for generating kernel data structures and uAPI headers. - Expose all net/core sysctls inside netns. - Remove 4s sleep in netpoll if carrier is instantly detected on boot. - Add configurable limit of MDB entries per port, and port-vlan. - Continue populating drop reasons throughout the stack. - Retire a handful of legacy Qdiscs and classifiers. Protocols: - Support IPv4 big TCP (TSO frames larger than 64kB). - Add IP_LOCAL_PORT_RANGE socket option, to control local port range on socket by socket basis. - Track and report in procfs number of MPTCP sockets used. - Support mixing IPv4 and IPv6 flows in the in-kernel MPTCP path manager. - IPv6: don't check net.ipv6.route.max_size and rely on garbage collection to free memory (similarly to IPv4). - Support Penultimate Segment Pop (PSP) flavor in SRv6 (RFC8986). - ICMP: add per-rate limit counters. - Add support for user scanning requests in ieee802154. - Remove static WEP support. - Support minimal Wi-Fi 7 Extremely High Throughput (EHT) rate reporting. - WiFi 7 EHT channel puncturing support (client & AP). BPF: - Add a rbtree data structure following the "next-gen data structure" precedent set by recently added linked list, that is, by using kfunc + kptr instead of adding a new BPF map type. - Expose XDP hints via kfuncs with initial support for RX hash and timestamp metadata. - Add BPF_F_NO_TUNNEL_KEY extension to bpf_skb_set_tunnel_key to better support decap on GRE tunnel devices not operating in collect metadata. - Improve x86 JIT's codegen for PROBE_MEM runtime error checks. - Remove the need for trace_printk_lock for bpf_trace_printk and bpf_trace_vprintk helpers. - Extend libbpf's bpf_tracing.h support for tracing arguments of kprobes/uprobes and syscall as a special case. - Significantly reduce the search time for module symbols by livepatch and BPF. - Enable cpumasks to be used as kptrs, which is useful for tracing programs tracking which tasks end up running on which CPUs in different time intervals. - Add support for BPF trampoline on s390x and riscv64. - Add capability to export the XDP features supported by the NIC. - Add __bpf_kfunc tag for marking kernel functions as kfuncs. - Add cgroup.memory=nobpf kernel parameter option to disable BPF memory accounting for container environments. Netfilter: - Remove the CLUSTERIP target. It has been marked as obsolete for years, and we still have WARN splats wrt races of the out-of-band /proc interface installed by this target. - Add 'destroy' commands to nf_tables. They are identical to the existing 'delete' commands, but do not return an error if the referenced object (set, chain, rule...) did not exist. Driver API: - Improve cpumask_local_spread() locality to help NICs set the right IRQ affinity on AMD platforms. - Separate C22 and C45 MDIO bus transactions more clearly. - Introduce new DCB table to control DSCP rewrite on egress. - Support configuration of Physical Layer Collision Avoidance (PLCA) Reconciliation Sublayer (RS) (802.3cg-2019). Modern version of shared medium Ethernet. - Support for MAC Merge layer (IEEE 802.3-2018 clause 99). Allowing preemption of low priority frames by high priority frames. - Add support for controlling MACSec offload using netlink SET. - Rework devlink instance refcounts to allow registration and de-registration under the instance lock. Split the code into multiple files, drop some of the unnecessarily granular locks and factor out common parts of netlink operation handling. - Add TX frame aggregation parameters (for USB drivers). - Add a new attr TCA_EXT_WARN_MSG to report TC (offload) warning messages with notifications for debug. - Allow offloading of UDP NEW connections via act_ct. - Add support for per action HW stats in TC. - Support hardware miss to TC action (continue processing in SW from a specific point in the action chain). - Warn if old Wireless Extension user space interface is used with modern cfg80211/mac80211 drivers. Do not support Wireless Extensions for Wi-Fi 7 devices at all. Everyone should switch to using nl80211 interface instead. - Improve the CAN bit timing configuration. Use extack to return error messages directly to user space, update the SJW handling, including the definition of a new default value that will benefit CAN-FD controllers, by increasing their oscillator tolerance. New hardware / drivers: - Ethernet: - nVidia BlueField-3 support (control traffic driver) - Ethernet support for imx93 SoCs - Motorcomm yt8531 gigabit Ethernet PHY - onsemi NCN26000 10BASE-T1S PHY (with support for PLCA) - Microchip LAN8841 PHY (incl. cable diagnostics and PTP) - Amlogic gxl MDIO mux - WiFi: - RealTek RTL8188EU (rtl8xxxu) - Qualcomm Wi-Fi 7 devices (ath12k) - CAN: - Renesas R-Car V4H Drivers: - Bluetooth: - Set Per Platform Antenna Gain (PPAG) for Intel controllers. - Ethernet NICs: - Intel (1G, igc): - support TSN / Qbv / packet scheduling features of i226 model - Intel (100G, ice): - use GNSS subsystem instead of TTY - multi-buffer XDP support - extend support for GPIO pins to E823 devices - nVidia/Mellanox: - update the shared buffer configuration on PFC commands - implement PTP adjphase function for HW offset control - TC support for Geneve and GRE with VF tunnel offload - more efficient crypto key management method - multi-port eswitch support - Netronome/Corigine: - add DCB IEEE support - support IPsec offloading for NFP3800 - Freescale/NXP (enetc): - support XDP_REDIRECT for XDP non-linear buffers - improve reconfig, avoid link flap and waiting for idle - support MAC Merge layer - Other NICs: - sfc/ef100: add basic devlink support for ef100 - ionic: rx_push mode operation (writing descriptors via MMIO) - bnxt: use the auxiliary bus abstraction for RDMA - r8169: disable ASPM and reset bus in case of tx timeout - cpsw: support QSGMII mode for J721e CPSW9G - cpts: support pulse-per-second output - ngbe: add an mdio bus driver - usbnet: optimize usbnet_bh() by avoiding unnecessary queuing - r8152: handle devices with FW with NCM support - amd-xgbe: support 10Mbps, 2.5GbE speeds and rx-adaptation - virtio-net: support multi buffer XDP - virtio/vsock: replace virtio_vsock_pkt with sk_buff - tsnep: XDP support - Ethernet high-speed switches: - nVidia/Mellanox (mlxsw): - add support for latency TLV (in FW control messages) - Microchip (sparx5): - separate explicit and implicit traffic forwarding rules, make the implicit rules always active - add support for egress DSCP rewrite - IS0 VCAP support (Ingress Classification) - IS2 VCAP filters (protos, L3 addrs, L4 ports, flags, ToS etc.) - ES2 VCAP support (Egress Access Control) - support for Per-Stream Filtering and Policing (802.1Q, 8.6.5.1) - Ethernet embedded switches: - Marvell (mv88e6xxx): - add MAB (port auth) offload support - enable PTP receive for mv88e6390 - NXP (ocelot): - support MAC Merge layer - support for the the vsc7512 internal copper phys - Microchip: - lan9303: convert to PHYLINK - lan966x: support TC flower filter statistics - lan937x: PTP support for KSZ9563/KSZ8563 and LAN937x - lan937x: support Credit Based Shaper configuration - ksz9477: support Energy Efficient Ethernet - other: - qca8k: convert to regmap read/write API, use bulk operations - rswitch: Improve TX timestamp accuracy - Intel WiFi (iwlwifi): - EHT (Wi-Fi 7) rate reporting - STEP equalizer support: transfer some STEP (connection to radio on platforms with integrated wifi) related parameters from the BIOS to the firmware. - Qualcomm 802.11ax WiFi (ath11k): - IPQ5018 support - Fine Timing Measurement (FTM) responder role support - channel 177 support - MediaTek WiFi (mt76): - per-PHY LED support - mt7996: EHT (Wi-Fi 7) support - Wireless Ethernet Dispatch (WED) reset support - switch to using page pool allocator - RealTek WiFi (rtw89): - support new version of Bluetooth co-existance - Mobile: - rmnet: support TX aggregation" * tag 'net-next-6.3' of git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net-next: (1872 commits) page_pool: add a comment explaining the fragment counter usage net: ethtool: fix __ethtool_dev_mm_supported() implementation ethtool: pse-pd: Fix double word in comments xsk: add linux/vmalloc.h to xsk.c sefltests: netdevsim: wait for devlink instance after netns removal selftest: fib_tests: Always cleanup before exit net/mlx5e: Align IPsec ASO result memory to be as required by hardware net/mlx5e: TC, Set CT miss to the specific ct action instance net/mlx5e: Rename CHAIN_TO_REG to MAPPED_OBJ_TO_REG net/mlx5: Refactor tc miss handling to a single function net/mlx5: Kconfig: Make tc offload depend on tc skb extension net/sched: flower: Support hardware miss to tc action net/sched: flower: Move filter handle initialization earlier net/sched: cls_api: Support hardware miss to tc action net/sched: Rename user cookie and act cookie sfc: fix builds without CONFIG_RTC_LIB sfc: clean up some inconsistent indentings net/mlx4_en: Introduce flexible array to silence overflow warning net: lan966x: Fix possible deadlock inside PTP net/ulp: Remove redundant ->clone() test in inet_clone_ulp(). ...
Diffstat (limited to '')
-rw-r--r--tools/perf/pmu-events/arch/arm64/common-and-microarch.json812
1 files changed, 812 insertions, 0 deletions
diff --git a/tools/perf/pmu-events/arch/arm64/common-and-microarch.json b/tools/perf/pmu-events/arch/arm64/common-and-microarch.json
new file mode 100644
index 000000000..492083b99
--- /dev/null
+++ b/tools/perf/pmu-events/arch/arm64/common-and-microarch.json
@@ -0,0 +1,812 @@
+[
+ {
+ "PublicDescription": "Instruction architecturally executed, Condition code check pass, software increment",
+ "EventCode": "0x00",
+ "EventName": "SW_INCR",
+ "BriefDescription": "Instruction architecturally executed, Condition code check pass, software increment"
+ },
+ {
+ "PublicDescription": "Level 1 instruction cache refill",
+ "EventCode": "0x01",
+ "EventName": "L1I_CACHE_REFILL",
+ "BriefDescription": "Level 1 instruction cache refill"
+ },
+ {
+ "PublicDescription": "Attributable Level 1 instruction TLB refill",
+ "EventCode": "0x02",
+ "EventName": "L1I_TLB_REFILL",
+ "BriefDescription": "Attributable Level 1 instruction TLB refill"
+ },
+ {
+ "PublicDescription": "Level 1 data cache refill",
+ "EventCode": "0x03",
+ "EventName": "L1D_CACHE_REFILL",
+ "BriefDescription": "Level 1 data cache refill"
+ },
+ {
+ "PublicDescription": "Level 1 data cache access",
+ "EventCode": "0x04",
+ "EventName": "L1D_CACHE",
+ "BriefDescription": "Level 1 data cache access"
+ },
+ {
+ "PublicDescription": "Attributable Level 1 data TLB refill",
+ "EventCode": "0x05",
+ "EventName": "L1D_TLB_REFILL",
+ "BriefDescription": "Attributable Level 1 data TLB refill"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, condition code check pass, load",
+ "EventCode": "0x06",
+ "EventName": "LD_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, condition code check pass, load"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, condition code check pass, store",
+ "EventCode": "0x07",
+ "EventName": "ST_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, condition code check pass, store"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed",
+ "EventCode": "0x08",
+ "EventName": "INST_RETIRED",
+ "BriefDescription": "Instruction architecturally executed"
+ },
+ {
+ "PublicDescription": "Exception taken",
+ "EventCode": "0x09",
+ "EventName": "EXC_TAKEN",
+ "BriefDescription": "Exception taken"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, condition check pass, exception return",
+ "EventCode": "0x0a",
+ "EventName": "EXC_RETURN",
+ "BriefDescription": "Instruction architecturally executed, condition check pass, exception return"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, condition code check pass, write to CONTEXTIDR",
+ "EventCode": "0x0b",
+ "EventName": "CID_WRITE_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, condition code check pass, write to CONTEXTIDR"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, condition code check pass, software change of the PC",
+ "EventCode": "0x0C",
+ "EventName": "PC_WRITE_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, condition code check pass, software change of the PC"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, immediate branch",
+ "EventCode": "0x0D",
+ "EventName": "BR_IMMED_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, immediate branch"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, condition code check pass, procedure return",
+ "EventCode": "0x0E",
+ "EventName": "BR_RETURN_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, condition code check pass, procedure return"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, condition code check pass, unaligned",
+ "EventCode": "0x0F",
+ "EventName": "UNALIGNED_LDST_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, condition code check pass, unaligned"
+ },
+ {
+ "PublicDescription": "Mispredicted or not predicted branch speculatively executed",
+ "EventCode": "0x10",
+ "EventName": "BR_MIS_PRED",
+ "BriefDescription": "Mispredicted or not predicted branch speculatively executed"
+ },
+ {
+ "PublicDescription": "Cycle",
+ "EventCode": "0x11",
+ "EventName": "CPU_CYCLES",
+ "BriefDescription": "Cycle"
+ },
+ {
+ "PublicDescription": "Predictable branch speculatively executed",
+ "EventCode": "0x12",
+ "EventName": "BR_PRED",
+ "BriefDescription": "Predictable branch speculatively executed"
+ },
+ {
+ "PublicDescription": "Data memory access",
+ "EventCode": "0x13",
+ "EventName": "MEM_ACCESS",
+ "BriefDescription": "Data memory access"
+ },
+ {
+ "PublicDescription": "Attributable Level 1 instruction cache access",
+ "EventCode": "0x14",
+ "EventName": "L1I_CACHE",
+ "BriefDescription": "Attributable Level 1 instruction cache access"
+ },
+ {
+ "PublicDescription": "Attributable Level 1 data cache write-back",
+ "EventCode": "0x15",
+ "EventName": "L1D_CACHE_WB",
+ "BriefDescription": "Attributable Level 1 data cache write-back"
+ },
+ {
+ "PublicDescription": "Level 2 data cache access",
+ "EventCode": "0x16",
+ "EventName": "L2D_CACHE",
+ "BriefDescription": "Level 2 data cache access"
+ },
+ {
+ "PublicDescription": "Level 2 data refill",
+ "EventCode": "0x17",
+ "EventName": "L2D_CACHE_REFILL",
+ "BriefDescription": "Level 2 data refill"
+ },
+ {
+ "PublicDescription": "Attributable Level 2 data cache write-back",
+ "EventCode": "0x18",
+ "EventName": "L2D_CACHE_WB",
+ "BriefDescription": "Attributable Level 2 data cache write-back"
+ },
+ {
+ "PublicDescription": "Attributable Bus access",
+ "EventCode": "0x19",
+ "EventName": "BUS_ACCESS",
+ "BriefDescription": "Attributable Bus access"
+ },
+ {
+ "PublicDescription": "Local memory error",
+ "EventCode": "0x1a",
+ "EventName": "MEMORY_ERROR",
+ "BriefDescription": "Local memory error"
+ },
+ {
+ "PublicDescription": "Operation speculatively executed",
+ "EventCode": "0x1b",
+ "EventName": "INST_SPEC",
+ "BriefDescription": "Operation speculatively executed"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, Condition code check pass, write to TTBR",
+ "EventCode": "0x1c",
+ "EventName": "TTBR_WRITE_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, Condition code check pass, write to TTBR"
+ },
+ {
+ "PublicDescription": "Bus cycle",
+ "EventCode": "0x1D",
+ "EventName": "BUS_CYCLES",
+ "BriefDescription": "Bus cycle"
+ },
+ {
+ "PublicDescription": "Level 1 data cache allocation without refill",
+ "EventCode": "0x1F",
+ "EventName": "L1D_CACHE_ALLOCATE",
+ "BriefDescription": "Level 1 data cache allocation without refill"
+ },
+ {
+ "PublicDescription": "Attributable Level 2 data cache allocation without refill",
+ "EventCode": "0x20",
+ "EventName": "L2D_CACHE_ALLOCATE",
+ "BriefDescription": "Attributable Level 2 data cache allocation without refill"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, branch",
+ "EventCode": "0x21",
+ "EventName": "BR_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, branch"
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, mispredicted branch",
+ "EventCode": "0x22",
+ "EventName": "BR_MIS_PRED_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, mispredicted branch"
+ },
+ {
+ "PublicDescription": "No operation issued because of the frontend",
+ "EventCode": "0x23",
+ "EventName": "STALL_FRONTEND",
+ "BriefDescription": "No operation issued because of the frontend"
+ },
+ {
+ "PublicDescription": "No operation issued due to the backend",
+ "EventCode": "0x24",
+ "EventName": "STALL_BACKEND",
+ "BriefDescription": "No operation issued due to the backend"
+ },
+ {
+ "PublicDescription": "Attributable Level 1 data or unified TLB access",
+ "EventCode": "0x25",
+ "EventName": "L1D_TLB",
+ "BriefDescription": "Attributable Level 1 data or unified TLB access"
+ },
+ {
+ "PublicDescription": "Attributable Level 1 instruction TLB access",
+ "EventCode": "0x26",
+ "EventName": "L1I_TLB",
+ "BriefDescription": "Attributable Level 1 instruction TLB access"
+ },
+ {
+ "PublicDescription": "Attributable Level 3 data cache allocation without refill",
+ "EventCode": "0x29",
+ "EventName": "L3D_CACHE_ALLOCATE",
+ "BriefDescription": "Attributable Level 3 data cache allocation without refill"
+ },
+ {
+ "PublicDescription": "Attributable Level 3 data cache refill",
+ "EventCode": "0x2A",
+ "EventName": "L3D_CACHE_REFILL",
+ "BriefDescription": "Attributable Level 3 data cache refill"
+ },
+ {
+ "PublicDescription": "Attributable Level 3 data cache access",
+ "EventCode": "0x2B",
+ "EventName": "L3D_CACHE",
+ "BriefDescription": "Attributable Level 3 data cache access"
+ },
+ {
+ "PublicDescription": "Attributable Level 2 data TLB refill",
+ "EventCode": "0x2D",
+ "EventName": "L2D_TLB_REFILL",
+ "BriefDescription": "Attributable Level 2 data TLB refill"
+ },
+ {
+ "PublicDescription": "Attributable Level 2 instruction TLB refill.",
+ "EventCode": "0x2E",
+ "EventName": "L2I_TLB_REFILL",
+ "BriefDescription": "Attributable Level 2 instruction TLB refill."
+ },
+ {
+ "PublicDescription": "Attributable Level 2 data or unified TLB access",
+ "EventCode": "0x2F",
+ "EventName": "L2D_TLB",
+ "BriefDescription": "Attributable Level 2 data or unified TLB access"
+ },
+ {
+ "PublicDescription": "Attributable Level 2 instruction TLB access.",
+ "EventCode": "0x30",
+ "EventName": "L2I_TLB",
+ "BriefDescription": "Attributable Level 2 instruction TLB access."
+ },
+ {
+ "PublicDescription": "Access to another socket in a multi-socket system",
+ "EventCode": "0x31",
+ "EventName": "REMOTE_ACCESS",
+ "BriefDescription": "Access to another socket in a multi-socket system"
+ },
+ {
+ "PublicDescription": "Access to data TLB causes a translation table walk",
+ "EventCode": "0x34",
+ "EventName": "DTLB_WALK",
+ "BriefDescription": "Access to data TLB causes a translation table walk"
+ },
+ {
+ "PublicDescription": "Access to instruction TLB that causes a translation table walk",
+ "EventCode": "0x35",
+ "EventName": "ITLB_WALK",
+ "BriefDescription": "Access to instruction TLB that causes a translation table walk"
+ },
+ {
+ "PublicDescription": "Attributable Last level cache memory read",
+ "EventCode": "0x36",
+ "EventName": "LL_CACHE_RD",
+ "BriefDescription": "Attributable Last level cache memory read"
+ },
+ {
+ "PublicDescription": "Last level cache miss, read",
+ "EventCode": "0x37",
+ "EventName": "LL_CACHE_MISS_RD",
+ "BriefDescription": "Last level cache miss, read"
+ },
+ {
+ "PublicDescription": "Attributable memory read access to another socket in a multi-socket system",
+ "EventCode": "0x38",
+ "EventName": "REMOTE_ACCESS_RD",
+ "BriefDescription": "Attributable memory read access to another socket in a multi-socket system"
+ },
+ {
+ "PublicDescription": "Level 1 data cache long-latency read miss. The counter counts each memory read access counted by L1D_CACHE that incurs additional latency because it returns data from outside the Level 1 data or unified cache of this processing element.",
+ "EventCode": "0x39",
+ "EventName": "L1D_CACHE_LMISS_RD",
+ "BriefDescription": "Level 1 data cache long-latency read miss"
+ },
+ {
+ "PublicDescription": "Micro-operation architecturally executed. The counter counts each operation counted by OP_SPEC that would be executed in a simple sequential execution of the program.",
+ "EventCode": "0x3A",
+ "EventName": "OP_RETIRED",
+ "BriefDescription": "Micro-operation architecturally executed"
+ },
+ {
+ "PublicDescription": "Micro-operation speculatively executed. The counter counts the number of operations executed by the processing element, including those that are executed speculatively and would not be executed in a simple sequential execution of the program.",
+ "EventCode": "0x3B",
+ "EventName": "OP_SPEC",
+ "BriefDescription": "Micro-operation speculatively executed"
+ },
+ {
+ "PublicDescription": "No operation sent for execution. The counter counts every attributable cycle on which no attributable instruction or operation was sent for execution on this processing element.",
+ "EventCode": "0x3C",
+ "EventName": "STALL",
+ "BriefDescription": "No operation sent for execution"
+ },
+ {
+ "PublicDescription": "No operation sent for execution on a slot due to the backend. Counts each slot counted by STALL_SLOT where no attributable instruction or operation was sent for execution because the backend is unable to accept it.",
+ "EventCode": "0x3D",
+ "EventName": "STALL_SLOT_BACKEND",
+ "BriefDescription": "No operation sent for execution on a slot due to the backend"
+ },
+ {
+ "PublicDescription": "No operation sent for execution on a slot due to the frontend. Counts each slot counted by STALL_SLOT where no attributable instruction or operation was sent for execution because there was no attributable instruction or operation available to issue from the processing element from the frontend for the slot.",
+ "EventCode": "0x3E",
+ "EventName": "STALL_SLOT_FRONTEND",
+ "BriefDescription": "No operation sent for execution on a slot due to the frontend"
+ },
+ {
+ "PublicDescription": "No operation sent for execution on a slot. The counter counts on each attributable cycle the number of instruction or operation slots that were not occupied by an instruction or operation attributable to the processing element.",
+ "EventCode": "0x3F",
+ "EventName": "STALL_SLOT",
+ "BriefDescription": "No operation sent for execution on a slot"
+ },
+ {
+ "PublicDescription": "Sample Population",
+ "EventCode": "0x4000",
+ "EventName": "SAMPLE_POP",
+ "BriefDescription": "Sample Population"
+ },
+ {
+ "PublicDescription": "Sample Taken",
+ "EventCode": "0x4001",
+ "EventName": "SAMPLE_FEED",
+ "BriefDescription": "Sample Taken"
+ },
+ {
+ "PublicDescription": "Sample Taken and not removed by filtering",
+ "EventCode": "0x4002",
+ "EventName": "SAMPLE_FILTRATE",
+ "BriefDescription": "Sample Taken and not removed by filtering"
+ },
+ {
+ "PublicDescription": "Sample collided with previous sample",
+ "EventCode": "0x4003",
+ "EventName": "SAMPLE_COLLISION",
+ "BriefDescription": "Sample collided with previous sample"
+ },
+ {
+ "PublicDescription": "Constant frequency cycles. The counter increments at a constant frequency equal to the rate of increment of the system counter, CNTPCT_EL0.",
+ "EventCode": "0x4004",
+ "EventName": "CNT_CYCLES",
+ "BriefDescription": "Constant frequency cycles"
+ },
+ {
+ "PublicDescription": "Memory stall cycles. The counter counts each cycle counted by STALL_BACKEND where there is a cache miss in the last level of cache within the processing element clock domain",
+ "EventCode": "0x4005",
+ "EventName": "STALL_BACKEND_MEM",
+ "BriefDescription": "Memory stall cycles"
+ },
+ {
+ "PublicDescription": "Level 1 instruction cache long-latency read miss. If the L1I_CACHE_RD event is implemented, the counter counts each access counted by L1I_CACHE_RD that incurs additional latency because it returns instructions from outside of the Level 1 instruction cache of this PE. If the L1I_CACHE_RD event is not implemented, the counter counts each access counted by L1I_CACHE that incurs additional latency because it returns instructions from outside the Level 1 instruction cache of this PE. The event indicates to software that the access missed in the Level 1 instruction cache and might have a significant performance impact due to the additional latency, compared to the latency of an access that hits in the Level 1 instruction cache.",
+ "EventCode": "0x4006",
+ "EventName": "L1I_CACHE_LMISS",
+ "BriefDescription": "Level 1 instruction cache long-latency read miss"
+ },
+ {
+ "PublicDescription": "Level 2 data cache long-latency read miss. The counter counts each memory read access counted by L2D_CACHE that incurs additional latency because it returns data from outside the Level 2 data or unified cache of this processing element. The event indicates to software that the access missed in the Level 2 data or unified cache and might have a significant performance impact compared to the latency of an access that hits in the Level 2 data or unified cache.",
+ "EventCode": "0x4009",
+ "EventName": "L2D_CACHE_LMISS_RD",
+ "BriefDescription": "Level 2 data cache long-latency read miss"
+ },
+ {
+ "PublicDescription": "Level 3 data cache long-latency read miss. The counter counts each memory read access counted by L3D_CACHE that incurs additional latency because it returns data from outside the Level 3 data or unified cache of this processing element. The event indicates to software that the access missed in the Level 3 data or unified cache and might have a significant performance impact compared to the latency of an access that hits in the Level 3 data or unified cache.",
+ "EventCode": "0x400B",
+ "EventName": "L3D_CACHE_LMISS_RD",
+ "BriefDescription": "Level 3 data cache long-latency read miss"
+ },
+ {
+ "PublicDescription": "Trace buffer current write pointer wrapped",
+ "EventCode": "0x400C",
+ "EventName": "TRB_WRAP",
+ "BriefDescription": "Trace buffer current write pointer wrapped"
+ },
+ {
+ "PublicDescription": "PMU overflow, counters accessible to EL1 and EL0",
+ "EventCode": "0x400D",
+ "EventName": "PMU_OVFS",
+ "BriefDescription": "PMU overflow, counters accessible to EL1 and EL0"
+ },
+ {
+ "PublicDescription": "Trace buffer Trigger Event",
+ "EventCode": "0x400E",
+ "EventName": "TRB_TRIG",
+ "BriefDescription": "Trace buffer Trigger Event"
+ },
+ {
+ "PublicDescription": "PMU overflow, counters reserved for use by EL2",
+ "EventCode": "0x400F",
+ "EventName": "PMU_HOVFS",
+ "BriefDescription": "PMU overflow, counters reserved for use by EL2"
+ },
+ {
+ "PublicDescription": "PE Trace Unit external output 0",
+ "EventCode": "0x4010",
+ "EventName": "TRCEXTOUT0",
+ "BriefDescription": "PE Trace Unit external output 0"
+ },
+ {
+ "PublicDescription": "PE Trace Unit external output 1",
+ "EventCode": "0x4011",
+ "EventName": "TRCEXTOUT1",
+ "BriefDescription": "PE Trace Unit external output 1"
+ },
+ {
+ "PublicDescription": "PE Trace Unit external output 2",
+ "EventCode": "0x4012",
+ "EventName": "TRCEXTOUT2",
+ "BriefDescription": "PE Trace Unit external output 2"
+ },
+ {
+ "PublicDescription": "PE Trace Unit external output 3",
+ "EventCode": "0x4013",
+ "EventName": "TRCEXTOUT3",
+ "BriefDescription": "PE Trace Unit external output 3"
+ },
+ {
+ "PublicDescription": "Cross-trigger Interface output trigger 4",
+ "EventCode": "0x4018",
+ "EventName": "CTI_TRIGOUT4",
+ "BriefDescription": "Cross-trigger Interface output trigger 4"
+ },
+ {
+ "PublicDescription": "Cross-trigger Interface output trigger 5 ",
+ "EventCode": "0x4019",
+ "EventName": "CTI_TRIGOUT5",
+ "BriefDescription": "Cross-trigger Interface output trigger 5 "
+ },
+ {
+ "PublicDescription": "Cross-trigger Interface output trigger 6",
+ "EventCode": "0x401A",
+ "EventName": "CTI_TRIGOUT6",
+ "BriefDescription": "Cross-trigger Interface output trigger 6"
+ },
+ {
+ "PublicDescription": "Cross-trigger Interface output trigger 7",
+ "EventCode": "0x401B",
+ "EventName": "CTI_TRIGOUT7",
+ "BriefDescription": "Cross-trigger Interface output trigger 7"
+ },
+ {
+ "PublicDescription": "Access with additional latency from alignment",
+ "EventCode": "0x4020",
+ "EventName": "LDST_ALIGN_LAT",
+ "BriefDescription": "Access with additional latency from alignment"
+ },
+ {
+ "PublicDescription": "Load with additional latency from alignment",
+ "EventCode": "0x4021",
+ "EventName": "LD_ALIGN_LAT",
+ "BriefDescription": "Load with additional latency from alignment"
+ },
+ {
+ "PublicDescription": "Store with additional latency from alignment",
+ "EventCode": "0x4022",
+ "EventName": "ST_ALIGN_LAT",
+ "BriefDescription": "Store with additional latency from alignment"
+ },
+ {
+ "PublicDescription": "Checked data memory access",
+ "EventCode": "0x4024",
+ "EventName": "MEM_ACCESS_CHECKED",
+ "BriefDescription": "Checked data memory access"
+ },
+ {
+ "PublicDescription": "Checked data memory access, read",
+ "EventCode": "0x4025",
+ "EventName": "MEM_ACCESS_CHECKED_RD",
+ "BriefDescription": "Checked data memory access, read"
+ },
+ {
+ "PublicDescription": "Checked data memory access, write",
+ "EventCode": "0x4026",
+ "EventName": "MEM_ACCESS_CHECKED_WR",
+ "BriefDescription": "Checked data memory access, write"
+ },
+ {
+ "PublicDescription": "SIMD Instruction architecturally executed.",
+ "EventCode": "0x8000",
+ "EventName": "SIMD_INST_RETIRED",
+ "BriefDescription": "SIMD Instruction architecturally executed."
+ },
+ {
+ "PublicDescription": "Instruction architecturally executed, SVE.",
+ "EventCode": "0x8002",
+ "EventName": "SVE_INST_RETIRED",
+ "BriefDescription": "Instruction architecturally executed, SVE."
+ },
+ {
+ "PublicDescription": "ASE operations speculatively executed",
+ "EventCode": "0x8005",
+ "EventName": "ASE_INST_SPEC",
+ "BriefDescription": "ASE operations speculatively executed"
+ },
+ {
+ "PublicDescription": "SVE operations speculatively executed",
+ "EventCode": "0x8006",
+ "EventName": "SVE_INST_SPEC",
+ "BriefDescription": "SVE operations speculatively executed"
+ },
+ {
+ "PublicDescription": "Microarchitectural operation, Operations speculatively executed.",
+ "EventCode": "0x8008",
+ "EventName": "UOP_SPEC",
+ "BriefDescription": "Microarchitectural operation, Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE Math accelerator Operations speculatively executed.",
+ "EventCode": "0x800E",
+ "EventName": "SVE_MATH_SPEC",
+ "BriefDescription": "SVE Math accelerator Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Floating-point Operations speculatively executed.",
+ "EventCode": "0x8010",
+ "EventName": "FP_SPEC",
+ "BriefDescription": "Floating-point Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Floating-point half-precision operations speculatively executed",
+ "EventCode": "0x8014",
+ "EventName": "FP_HP_SPEC",
+ "BriefDescription": "Floating-point half-precision operations speculatively executed"
+ },
+ {
+ "PublicDescription": "Floating-point single-precision operations speculatively executed",
+ "EventCode": "0x8018",
+ "EventName": "FP_SP_SPEC",
+ "BriefDescription": "Floating-point single-precision operations speculatively executed"
+ },
+ {
+ "PublicDescription": "Floating-point double-precision operations speculatively executed",
+ "EventCode": "0x801C",
+ "EventName": "FP_DP_SPEC",
+ "BriefDescription": "Floating-point double-precision operations speculatively executed"
+ },
+ {
+ "PublicDescription": "Floating-point FMA Operations speculatively executed.",
+ "EventCode": "0x8028",
+ "EventName": "FP_FMA_SPEC",
+ "BriefDescription": "Floating-point FMA Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Floating-point reciprocal estimate Operations speculatively executed.",
+ "EventCode": "0x8034",
+ "EventName": "FP_RECPE_SPEC",
+ "BriefDescription": "Floating-point reciprocal estimate Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "floating-point convert Operations speculatively executed.",
+ "EventCode": "0x8038",
+ "EventName": "FP_CVT_SPEC",
+ "BriefDescription": "floating-point convert Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Advanced SIMD and SVE integer Operations speculatively executed.",
+ "EventCode": "0x8043",
+ "EventName": "ASE_SVE_INT_SPEC",
+ "BriefDescription": "Advanced SIMD and SVE integer Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE predicated Operations speculatively executed.",
+ "EventCode": "0x8074",
+ "EventName": "SVE_PRED_SPEC",
+ "BriefDescription": "SVE predicated Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE predicated operations with no active predicates speculatively executed",
+ "EventCode": "0x8075",
+ "EventName": "SVE_PRED_EMPTY_SPEC",
+ "BriefDescription": "SVE predicated operations with no active predicates speculatively executed"
+ },
+ {
+ "PublicDescription": "SVE predicated operations speculatively executed with all active predicates",
+ "EventCode": "0x8076",
+ "EventName": "SVE_PRED_FULL_SPEC",
+ "BriefDescription": "SVE predicated operations speculatively executed with all active predicates"
+ },
+ {
+ "PublicDescription": "SVE predicated operations speculatively executed with partially active predicates",
+ "EventCode": "0x8077",
+ "EventName": "SVE_PRED_PARTIAL_SPEC",
+ "BriefDescription": "SVE predicated operations speculatively executed with partially active predicates"
+ },
+ {
+ "PublicDescription": "SVE predicated operations with empty or partially active predicates",
+ "EventCode": "0x8079",
+ "EventName": "SVE_PRED_NOT_FULL_SPEC",
+ "BriefDescription": "SVE predicated operations with empty or partially active predicates"
+ },
+ {
+ "PublicDescription": "SVE MOVPRFX Operations speculatively executed.",
+ "EventCode": "0x807C",
+ "EventName": "SVE_MOVPRFX_SPEC",
+ "BriefDescription": "SVE MOVPRFX Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE MOVPRFX unfused Operations speculatively executed.",
+ "EventCode": "0x807F",
+ "EventName": "SVE_MOVPRFX_U_SPEC",
+ "BriefDescription": "SVE MOVPRFX unfused Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Advanced SIMD and SVE load Operations speculatively executed.",
+ "EventCode": "0x8085",
+ "EventName": "ASE_SVE_LD_SPEC",
+ "BriefDescription": "Advanced SIMD and SVE load Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Advanced SIMD and SVE store Operations speculatively executed.",
+ "EventCode": "0x8086",
+ "EventName": "ASE_SVE_ST_SPEC",
+ "BriefDescription": "Advanced SIMD and SVE store Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Prefetch Operations speculatively executed.",
+ "EventCode": "0x8087",
+ "EventName": "PRF_SPEC",
+ "BriefDescription": "Prefetch Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "General-purpose register load Operations speculatively executed.",
+ "EventCode": "0x8089",
+ "EventName": "BASE_LD_REG_SPEC",
+ "BriefDescription": "General-purpose register load Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "General-purpose register store Operations speculatively executed.",
+ "EventCode": "0x808A",
+ "EventName": "BASE_ST_REG_SPEC",
+ "BriefDescription": "General-purpose register store Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE unpredicated load register Operations speculatively executed.",
+ "EventCode": "0x8091",
+ "EventName": "SVE_LDR_REG_SPEC",
+ "BriefDescription": "SVE unpredicated load register Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE unpredicated store register Operations speculatively executed.",
+ "EventCode": "0x8092",
+ "EventName": "SVE_STR_REG_SPEC",
+ "BriefDescription": "SVE unpredicated store register Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE load predicate register Operations speculatively executed.",
+ "EventCode": "0x8095",
+ "EventName": "SVE_LDR_PREG_SPEC",
+ "BriefDescription": "SVE load predicate register Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE store predicate register Operations speculatively executed.",
+ "EventCode": "0x8096",
+ "EventName": "SVE_STR_PREG_SPEC",
+ "BriefDescription": "SVE store predicate register Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE contiguous prefetch element Operations speculatively executed.",
+ "EventCode": "0x809F",
+ "EventName": "SVE_PRF_CONTIG_SPEC",
+ "BriefDescription": "SVE contiguous prefetch element Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Advanced SIMD and SVE contiguous load multiple vector Operations speculatively executed.",
+ "EventCode": "0x80A5",
+ "EventName": "ASE_SVE_LD_MULTI_SPEC",
+ "BriefDescription": "Advanced SIMD and SVE contiguous load multiple vector Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Advanced SIMD and SVE contiguous store multiple vector Operations speculatively executed.",
+ "EventCode": "0x80A6",
+ "EventName": "ASE_SVE_ST_MULTI_SPEC",
+ "BriefDescription": "Advanced SIMD and SVE contiguous store multiple vector Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE gather-load Operations speculatively executed.",
+ "EventCode": "0x80AD",
+ "EventName": "SVE_LD_GATHER_SPEC",
+ "BriefDescription": "SVE gather-load Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE scatter-store Operations speculatively executed.",
+ "EventCode": "0x80AE",
+ "EventName": "SVE_ST_SCATTER_SPEC",
+ "BriefDescription": "SVE scatter-store Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE gather-prefetch Operations speculatively executed.",
+ "EventCode": "0x80AF",
+ "EventName": "SVE_PRF_GATHER_SPEC",
+ "BriefDescription": "SVE gather-prefetch Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE First-fault load Operations speculatively executed.",
+ "EventCode": "0x80BC",
+ "EventName": "SVE_LDFF_SPEC",
+ "BriefDescription": "SVE First-fault load Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "SVE first-fault load operations speculatively executed which set FFR bit to 0",
+ "EventCode": "0x80BD",
+ "EventName": "SVE_LDFF_FAULT_SPEC",
+ "BriefDescription": "SVE first-fault load operations speculatively executed which set FFR bit to 0"
+ },
+ {
+ "PublicDescription": "Scalable floating-point element Operations speculatively executed.",
+ "EventCode": "0x80C0",
+ "EventName": "FP_SCALE_OPS_SPEC",
+ "BriefDescription": "Scalable floating-point element Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Non-scalable floating-point element Operations speculatively executed.",
+ "EventCode": "0x80C1",
+ "EventName": "FP_FIXED_OPS_SPEC",
+ "BriefDescription": "Non-scalable floating-point element Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Scalable half-precision floating-point element Operations speculatively executed.",
+ "EventCode": "0x80C2",
+ "EventName": "FP_HP_SCALE_OPS_SPEC",
+ "BriefDescription": "Scalable half-precision floating-point element Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Non-scalable half-precision floating-point element Operations speculatively executed.",
+ "EventCode": "0x80C3",
+ "EventName": "FP_HP_FIXED_OPS_SPEC",
+ "BriefDescription": "Non-scalable half-precision floating-point element Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Scalable single-precision floating-point element Operations speculatively executed.",
+ "EventCode": "0x80C4",
+ "EventName": "FP_SP_SCALE_OPS_SPEC",
+ "BriefDescription": "Scalable single-precision floating-point element Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Non-scalable single-precision floating-point element Operations speculatively executed.",
+ "EventCode": "0x80C5",
+ "EventName": "FP_SP_FIXED_OPS_SPEC",
+ "BriefDescription": "Non-scalable single-precision floating-point element Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Scalable double-precision floating-point element Operations speculatively executed.",
+ "EventCode": "0x80C6",
+ "EventName": "FP_DP_SCALE_OPS_SPEC",
+ "BriefDescription": "Scalable double-precision floating-point element Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Non-scalable double-precision floating-point element Operations speculatively executed.",
+ "EventCode": "0x80C7",
+ "EventName": "FP_DP_FIXED_OPS_SPEC",
+ "BriefDescription": "Non-scalable double-precision floating-point element Operations speculatively executed."
+ },
+ {
+ "PublicDescription": "Advanced SIMD and SVE 8-bit integer operations speculatively executed",
+ "EventCode": "0x80E3",
+ "EventName": "ASE_SVE_INT8_SPEC",
+ "BriefDescription": "Advanced SIMD and SVE 8-bit integer operations speculatively executed"
+ },
+ {
+ "PublicDescription": "Advanced SIMD and SVE 16-bit integer operations speculatively executed",
+ "EventCode": "0x80E7",
+ "EventName": "ASE_SVE_INT16_SPEC",
+ "BriefDescription": "Advanced SIMD and SVE 16-bit integer operations speculatively executed"
+ },
+ {
+ "PublicDescription": "Advanced SIMD and SVE 32-bit integer operations speculatively executed",
+ "EventCode": "0x80EB",
+ "EventName": "ASE_SVE_INT32_SPEC",
+ "BriefDescription": "Advanced SIMD and SVE 32-bit integer operations speculatively executed"
+ },
+ {
+ "PublicDescription": "Advanced SIMD and SVE 64-bit integer operations speculatively executed",
+ "EventCode": "0x80EF",
+ "EventName": "ASE_SVE_INT64_SPEC",
+ "BriefDescription": "Advanced SIMD and SVE 64-bit integer operations speculatively executed"
+ }
+]