aboutsummaryrefslogtreecommitdiff
path: root/Documentation/networking/device_drivers/ethernet/intel/i40e.rst
diff options
context:
space:
mode:
authorLibravatar Linus Torvalds <torvalds@linux-foundation.org>2023-02-21 18:24:12 -0800
committerLibravatar Linus Torvalds <torvalds@linux-foundation.org>2023-02-21 18:24:12 -0800
commit5b7c4cabbb65f5c469464da6c5f614cbd7f730f2 (patch)
treecc5c2d0a898769fd59549594fedb3ee6f84e59a0 /Documentation/networking/device_drivers/ethernet/intel/i40e.rst
downloadlinux-5b7c4cabbb65f5c469464da6c5f614cbd7f730f2.tar.gz
linux-5b7c4cabbb65f5c469464da6c5f614cbd7f730f2.zip
Merge tag 'net-next-6.3' of git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net-nextgrafted
Pull networking updates from Jakub Kicinski: "Core: - Add dedicated kmem_cache for typical/small skb->head, avoid having to access struct page at kfree time, and improve memory use. - Introduce sysctl to set default RPS configuration for new netdevs. - Define Netlink protocol specification format which can be used to describe messages used by each family and auto-generate parsers. Add tools for generating kernel data structures and uAPI headers. - Expose all net/core sysctls inside netns. - Remove 4s sleep in netpoll if carrier is instantly detected on boot. - Add configurable limit of MDB entries per port, and port-vlan. - Continue populating drop reasons throughout the stack. - Retire a handful of legacy Qdiscs and classifiers. Protocols: - Support IPv4 big TCP (TSO frames larger than 64kB). - Add IP_LOCAL_PORT_RANGE socket option, to control local port range on socket by socket basis. - Track and report in procfs number of MPTCP sockets used. - Support mixing IPv4 and IPv6 flows in the in-kernel MPTCP path manager. - IPv6: don't check net.ipv6.route.max_size and rely on garbage collection to free memory (similarly to IPv4). - Support Penultimate Segment Pop (PSP) flavor in SRv6 (RFC8986). - ICMP: add per-rate limit counters. - Add support for user scanning requests in ieee802154. - Remove static WEP support. - Support minimal Wi-Fi 7 Extremely High Throughput (EHT) rate reporting. - WiFi 7 EHT channel puncturing support (client & AP). BPF: - Add a rbtree data structure following the "next-gen data structure" precedent set by recently added linked list, that is, by using kfunc + kptr instead of adding a new BPF map type. - Expose XDP hints via kfuncs with initial support for RX hash and timestamp metadata. - Add BPF_F_NO_TUNNEL_KEY extension to bpf_skb_set_tunnel_key to better support decap on GRE tunnel devices not operating in collect metadata. - Improve x86 JIT's codegen for PROBE_MEM runtime error checks. - Remove the need for trace_printk_lock for bpf_trace_printk and bpf_trace_vprintk helpers. - Extend libbpf's bpf_tracing.h support for tracing arguments of kprobes/uprobes and syscall as a special case. - Significantly reduce the search time for module symbols by livepatch and BPF. - Enable cpumasks to be used as kptrs, which is useful for tracing programs tracking which tasks end up running on which CPUs in different time intervals. - Add support for BPF trampoline on s390x and riscv64. - Add capability to export the XDP features supported by the NIC. - Add __bpf_kfunc tag for marking kernel functions as kfuncs. - Add cgroup.memory=nobpf kernel parameter option to disable BPF memory accounting for container environments. Netfilter: - Remove the CLUSTERIP target. It has been marked as obsolete for years, and we still have WARN splats wrt races of the out-of-band /proc interface installed by this target. - Add 'destroy' commands to nf_tables. They are identical to the existing 'delete' commands, but do not return an error if the referenced object (set, chain, rule...) did not exist. Driver API: - Improve cpumask_local_spread() locality to help NICs set the right IRQ affinity on AMD platforms. - Separate C22 and C45 MDIO bus transactions more clearly. - Introduce new DCB table to control DSCP rewrite on egress. - Support configuration of Physical Layer Collision Avoidance (PLCA) Reconciliation Sublayer (RS) (802.3cg-2019). Modern version of shared medium Ethernet. - Support for MAC Merge layer (IEEE 802.3-2018 clause 99). Allowing preemption of low priority frames by high priority frames. - Add support for controlling MACSec offload using netlink SET. - Rework devlink instance refcounts to allow registration and de-registration under the instance lock. Split the code into multiple files, drop some of the unnecessarily granular locks and factor out common parts of netlink operation handling. - Add TX frame aggregation parameters (for USB drivers). - Add a new attr TCA_EXT_WARN_MSG to report TC (offload) warning messages with notifications for debug. - Allow offloading of UDP NEW connections via act_ct. - Add support for per action HW stats in TC. - Support hardware miss to TC action (continue processing in SW from a specific point in the action chain). - Warn if old Wireless Extension user space interface is used with modern cfg80211/mac80211 drivers. Do not support Wireless Extensions for Wi-Fi 7 devices at all. Everyone should switch to using nl80211 interface instead. - Improve the CAN bit timing configuration. Use extack to return error messages directly to user space, update the SJW handling, including the definition of a new default value that will benefit CAN-FD controllers, by increasing their oscillator tolerance. New hardware / drivers: - Ethernet: - nVidia BlueField-3 support (control traffic driver) - Ethernet support for imx93 SoCs - Motorcomm yt8531 gigabit Ethernet PHY - onsemi NCN26000 10BASE-T1S PHY (with support for PLCA) - Microchip LAN8841 PHY (incl. cable diagnostics and PTP) - Amlogic gxl MDIO mux - WiFi: - RealTek RTL8188EU (rtl8xxxu) - Qualcomm Wi-Fi 7 devices (ath12k) - CAN: - Renesas R-Car V4H Drivers: - Bluetooth: - Set Per Platform Antenna Gain (PPAG) for Intel controllers. - Ethernet NICs: - Intel (1G, igc): - support TSN / Qbv / packet scheduling features of i226 model - Intel (100G, ice): - use GNSS subsystem instead of TTY - multi-buffer XDP support - extend support for GPIO pins to E823 devices - nVidia/Mellanox: - update the shared buffer configuration on PFC commands - implement PTP adjphase function for HW offset control - TC support for Geneve and GRE with VF tunnel offload - more efficient crypto key management method - multi-port eswitch support - Netronome/Corigine: - add DCB IEEE support - support IPsec offloading for NFP3800 - Freescale/NXP (enetc): - support XDP_REDIRECT for XDP non-linear buffers - improve reconfig, avoid link flap and waiting for idle - support MAC Merge layer - Other NICs: - sfc/ef100: add basic devlink support for ef100 - ionic: rx_push mode operation (writing descriptors via MMIO) - bnxt: use the auxiliary bus abstraction for RDMA - r8169: disable ASPM and reset bus in case of tx timeout - cpsw: support QSGMII mode for J721e CPSW9G - cpts: support pulse-per-second output - ngbe: add an mdio bus driver - usbnet: optimize usbnet_bh() by avoiding unnecessary queuing - r8152: handle devices with FW with NCM support - amd-xgbe: support 10Mbps, 2.5GbE speeds and rx-adaptation - virtio-net: support multi buffer XDP - virtio/vsock: replace virtio_vsock_pkt with sk_buff - tsnep: XDP support - Ethernet high-speed switches: - nVidia/Mellanox (mlxsw): - add support for latency TLV (in FW control messages) - Microchip (sparx5): - separate explicit and implicit traffic forwarding rules, make the implicit rules always active - add support for egress DSCP rewrite - IS0 VCAP support (Ingress Classification) - IS2 VCAP filters (protos, L3 addrs, L4 ports, flags, ToS etc.) - ES2 VCAP support (Egress Access Control) - support for Per-Stream Filtering and Policing (802.1Q, 8.6.5.1) - Ethernet embedded switches: - Marvell (mv88e6xxx): - add MAB (port auth) offload support - enable PTP receive for mv88e6390 - NXP (ocelot): - support MAC Merge layer - support for the the vsc7512 internal copper phys - Microchip: - lan9303: convert to PHYLINK - lan966x: support TC flower filter statistics - lan937x: PTP support for KSZ9563/KSZ8563 and LAN937x - lan937x: support Credit Based Shaper configuration - ksz9477: support Energy Efficient Ethernet - other: - qca8k: convert to regmap read/write API, use bulk operations - rswitch: Improve TX timestamp accuracy - Intel WiFi (iwlwifi): - EHT (Wi-Fi 7) rate reporting - STEP equalizer support: transfer some STEP (connection to radio on platforms with integrated wifi) related parameters from the BIOS to the firmware. - Qualcomm 802.11ax WiFi (ath11k): - IPQ5018 support - Fine Timing Measurement (FTM) responder role support - channel 177 support - MediaTek WiFi (mt76): - per-PHY LED support - mt7996: EHT (Wi-Fi 7) support - Wireless Ethernet Dispatch (WED) reset support - switch to using page pool allocator - RealTek WiFi (rtw89): - support new version of Bluetooth co-existance - Mobile: - rmnet: support TX aggregation" * tag 'net-next-6.3' of git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net-next: (1872 commits) page_pool: add a comment explaining the fragment counter usage net: ethtool: fix __ethtool_dev_mm_supported() implementation ethtool: pse-pd: Fix double word in comments xsk: add linux/vmalloc.h to xsk.c sefltests: netdevsim: wait for devlink instance after netns removal selftest: fib_tests: Always cleanup before exit net/mlx5e: Align IPsec ASO result memory to be as required by hardware net/mlx5e: TC, Set CT miss to the specific ct action instance net/mlx5e: Rename CHAIN_TO_REG to MAPPED_OBJ_TO_REG net/mlx5: Refactor tc miss handling to a single function net/mlx5: Kconfig: Make tc offload depend on tc skb extension net/sched: flower: Support hardware miss to tc action net/sched: flower: Move filter handle initialization earlier net/sched: cls_api: Support hardware miss to tc action net/sched: Rename user cookie and act cookie sfc: fix builds without CONFIG_RTC_LIB sfc: clean up some inconsistent indentings net/mlx4_en: Introduce flexible array to silence overflow warning net: lan966x: Fix possible deadlock inside PTP net/ulp: Remove redundant ->clone() test in inet_clone_ulp(). ...
Diffstat (limited to 'Documentation/networking/device_drivers/ethernet/intel/i40e.rst')
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/i40e.rst771
1 files changed, 771 insertions, 0 deletions
diff --git a/Documentation/networking/device_drivers/ethernet/intel/i40e.rst b/Documentation/networking/device_drivers/ethernet/intel/i40e.rst
new file mode 100644
index 000000000..ac35bd472
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/i40e.rst
@@ -0,0 +1,771 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+=================================================================
+Linux Base Driver for the Intel(R) Ethernet Controller 700 Series
+=================================================================
+
+Intel 40 Gigabit Linux driver.
+Copyright(c) 1999-2018 Intel Corporation.
+
+Contents
+========
+
+- Overview
+- Identifying Your Adapter
+- Intel(R) Ethernet Flow Director
+- Additional Configurations
+- Known Issues
+- Support
+
+
+Driver information can be obtained using ethtool, lspci, and ifconfig.
+Instructions on updating ethtool can be found in the section Additional
+Configurations later in this document.
+
+For questions related to hardware requirements, refer to the documentation
+supplied with your Intel adapter. All hardware requirements listed apply to use
+with Linux.
+
+
+Identifying Your Adapter
+========================
+The driver is compatible with devices based on the following:
+
+ * Intel(R) Ethernet Controller X710
+ * Intel(R) Ethernet Controller XL710
+ * Intel(R) Ethernet Network Connection X722
+ * Intel(R) Ethernet Controller XXV710
+
+For the best performance, make sure the latest NVM/FW is installed on your
+device.
+
+For information on how to identify your adapter, and for the latest NVM/FW
+images and Intel network drivers, refer to the Intel Support website:
+https://www.intel.com/support
+
+SFP+ and QSFP+ Devices
+----------------------
+For information about supported media, refer to this document:
+https://www.intel.com/content/dam/www/public/us/en/documents/release-notes/xl710-ethernet-controller-feature-matrix.pdf
+
+NOTE: Some adapters based on the Intel(R) Ethernet Controller 700 Series only
+support Intel Ethernet Optics modules. On these adapters, other modules are not
+supported and will not function. In all cases Intel recommends using Intel
+Ethernet Optics; other modules may function but are not validated by Intel.
+Contact Intel for supported media types.
+
+NOTE: For connections based on Intel(R) Ethernet Controller 700 Series, support
+is dependent on your system board. Please see your vendor for details.
+
+NOTE: In systems that do not have adequate airflow to cool the adapter and
+optical modules, you must use high temperature optical modules.
+
+Virtual Functions (VFs)
+-----------------------
+Use sysfs to enable VFs. For example::
+
+ #echo $num_vf_enabled > /sys/class/net/$dev/device/sriov_numvfs #enable VFs
+ #echo 0 > /sys/class/net/$dev/device/sriov_numvfs #disable VFs
+
+For example, the following instructions will configure PF eth0 and the first VF
+on VLAN 10::
+
+ $ ip link set dev eth0 vf 0 vlan 10
+
+VLAN Tag Packet Steering
+------------------------
+Allows you to send all packets with a specific VLAN tag to a particular SR-IOV
+virtual function (VF). Further, this feature allows you to designate a
+particular VF as trusted, and allows that trusted VF to request selective
+promiscuous mode on the Physical Function (PF).
+
+To set a VF as trusted or untrusted, enter the following command in the
+Hypervisor::
+
+ # ip link set dev eth0 vf 1 trust [on|off]
+
+Once the VF is designated as trusted, use the following commands in the VM to
+set the VF to promiscuous mode.
+
+::
+
+ For promiscuous all:
+ #ip link set eth2 promisc on
+ Where eth2 is a VF interface in the VM
+
+ For promiscuous Multicast:
+ #ip link set eth2 allmulticast on
+ Where eth2 is a VF interface in the VM
+
+NOTE: By default, the ethtool priv-flag vf-true-promisc-support is set to
+"off",meaning that promiscuous mode for the VF will be limited. To set the
+promiscuous mode for the VF to true promiscuous and allow the VF to see all
+ingress traffic, use the following command::
+
+ #ethtool -set-priv-flags p261p1 vf-true-promisc-support on
+
+The vf-true-promisc-support priv-flag does not enable promiscuous mode; rather,
+it designates which type of promiscuous mode (limited or true) you will get
+when you enable promiscuous mode using the ip link commands above. Note that
+this is a global setting that affects the entire device. However,the
+vf-true-promisc-support priv-flag is only exposed to the first PF of the
+device. The PF remains in limited promiscuous mode (unless it is in MFP mode)
+regardless of the vf-true-promisc-support setting.
+
+Now add a VLAN interface on the VF interface::
+
+ #ip link add link eth2 name eth2.100 type vlan id 100
+
+Note that the order in which you set the VF to promiscuous mode and add the
+VLAN interface does not matter (you can do either first). The end result in
+this example is that the VF will get all traffic that is tagged with VLAN 100.
+
+Intel(R) Ethernet Flow Director
+-------------------------------
+The Intel Ethernet Flow Director performs the following tasks:
+
+- Directs receive packets according to their flows to different queues.
+- Enables tight control on routing a flow in the platform.
+- Matches flows and CPU cores for flow affinity.
+- Supports multiple parameters for flexible flow classification and load
+ balancing (in SFP mode only).
+
+NOTE: The Linux i40e driver supports the following flow types: IPv4, TCPv4, and
+UDPv4. For a given flow type, it supports valid combinations of IP addresses
+(source or destination) and UDP/TCP ports (source and destination). For
+example, you can supply only a source IP address, a source IP address and a
+destination port, or any combination of one or more of these four parameters.
+
+NOTE: The Linux i40e driver allows you to filter traffic based on a
+user-defined flexible two-byte pattern and offset by using the ethtool user-def
+and mask fields. Only L3 and L4 flow types are supported for user-defined
+flexible filters. For a given flow type, you must clear all Intel Ethernet Flow
+Director filters before changing the input set (for that flow type).
+
+To enable or disable the Intel Ethernet Flow Director::
+
+ # ethtool -K ethX ntuple <on|off>
+
+When disabling ntuple filters, all the user programmed filters are flushed from
+the driver cache and hardware. All needed filters must be re-added when ntuple
+is re-enabled.
+
+To add a filter that directs packet to queue 2, use -U or -N switch::
+
+ # ethtool -N ethX flow-type tcp4 src-ip 192.168.10.1 dst-ip \
+ 192.168.10.2 src-port 2000 dst-port 2001 action 2 [loc 1]
+
+To set a filter using only the source and destination IP address::
+
+ # ethtool -N ethX flow-type tcp4 src-ip 192.168.10.1 dst-ip \
+ 192.168.10.2 action 2 [loc 1]
+
+To see the list of filters currently present::
+
+ # ethtool <-u|-n> ethX
+
+Application Targeted Routing (ATR) Perfect Filters
+--------------------------------------------------
+ATR is enabled by default when the kernel is in multiple transmit queue mode.
+An ATR Intel Ethernet Flow Director filter rule is added when a TCP-IP flow
+starts and is deleted when the flow ends. When a TCP-IP Intel Ethernet Flow
+Director rule is added from ethtool (Sideband filter), ATR is turned off by the
+driver. To re-enable ATR, the sideband can be disabled with the ethtool -K
+option. For example::
+
+ ethtool -K [adapter] ntuple [off|on]
+
+If sideband is re-enabled after ATR is re-enabled, ATR remains enabled until a
+TCP-IP flow is added. When all TCP-IP sideband rules are deleted, ATR is
+automatically re-enabled.
+
+Packets that match the ATR rules are counted in fdir_atr_match stats in
+ethtool, which also can be used to verify whether ATR rules still exist.
+
+Sideband Perfect Filters
+------------------------
+Sideband Perfect Filters are used to direct traffic that matches specified
+characteristics. They are enabled through ethtool's ntuple interface. To add a
+new filter use the following command::
+
+ ethtool -U <device> flow-type <type> src-ip <ip> dst-ip <ip> src-port <port> \
+ dst-port <port> action <queue>
+
+Where:
+ <device> - the ethernet device to program
+ <type> - can be ip4, tcp4, udp4, or sctp4
+ <ip> - the ip address to match on
+ <port> - the port number to match on
+ <queue> - the queue to direct traffic towards (-1 discards matching traffic)
+
+Use the following command to display all of the active filters::
+
+ ethtool -u <device>
+
+Use the following command to delete a filter::
+
+ ethtool -U <device> delete <N>
+
+Where <N> is the filter id displayed when printing all the active filters, and
+may also have been specified using "loc <N>" when adding the filter.
+
+The following example matches TCP traffic sent from 192.168.0.1, port 5300,
+directed to 192.168.0.5, port 80, and sends it to queue 7::
+
+ ethtool -U enp130s0 flow-type tcp4 src-ip 192.168.0.1 dst-ip 192.168.0.5 \
+ src-port 5300 dst-port 80 action 7
+
+For each flow-type, the programmed filters must all have the same matching
+input set. For example, issuing the following two commands is acceptable::
+
+ ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7
+ ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.5 src-port 55 action 10
+
+Issuing the next two commands, however, is not acceptable, since the first
+specifies src-ip and the second specifies dst-ip::
+
+ ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7
+ ethtool -U enp130s0 flow-type ip4 dst-ip 192.168.0.5 src-port 55 action 10
+
+The second command will fail with an error. You may program multiple filters
+with the same fields, using different values, but, on one device, you may not
+program two tcp4 filters with different matching fields.
+
+Matching on a sub-portion of a field is not supported by the i40e driver, thus
+partial mask fields are not supported.
+
+The driver also supports matching user-defined data within the packet payload.
+This flexible data is specified using the "user-def" field of the ethtool
+command in the following way:
+
++----------------------------+--------------------------+
+| 31 28 24 20 16 | 15 12 8 4 0 |
++----------------------------+--------------------------+
+| offset into packet payload | 2 bytes of flexible data |
++----------------------------+--------------------------+
+
+For example,
+
+::
+
+ ... user-def 0x4FFFF ...
+
+tells the filter to look 4 bytes into the payload and match that value against
+0xFFFF. The offset is based on the beginning of the payload, and not the
+beginning of the packet. Thus
+
+::
+
+ flow-type tcp4 ... user-def 0x8BEAF ...
+
+would match TCP/IPv4 packets which have the value 0xBEAF 8 bytes into the
+TCP/IPv4 payload.
+
+Note that ICMP headers are parsed as 4 bytes of header and 4 bytes of payload.
+Thus to match the first byte of the payload, you must actually add 4 bytes to
+the offset. Also note that ip4 filters match both ICMP frames as well as raw
+(unknown) ip4 frames, where the payload will be the L3 payload of the IP4 frame.
+
+The maximum offset is 64. The hardware will only read up to 64 bytes of data
+from the payload. The offset must be even because the flexible data is 2 bytes
+long and must be aligned to byte 0 of the packet payload.
+
+The user-defined flexible offset is also considered part of the input set and
+cannot be programmed separately for multiple filters of the same type. However,
+the flexible data is not part of the input set and multiple filters may use the
+same offset but match against different data.
+
+To create filters that direct traffic to a specific Virtual Function, use the
+"action" parameter. Specify the action as a 64 bit value, where the lower 32
+bits represents the queue number, while the next 8 bits represent which VF.
+Note that 0 is the PF, so the VF identifier is offset by 1. For example::
+
+ ... action 0x800000002 ...
+
+specifies to direct traffic to Virtual Function 7 (8 minus 1) into queue 2 of
+that VF.
+
+Note that these filters will not break internal routing rules, and will not
+route traffic that otherwise would not have been sent to the specified Virtual
+Function.
+
+Setting the link-down-on-close Private Flag
+-------------------------------------------
+When the link-down-on-close private flag is set to "on", the port's link will
+go down when the interface is brought down using the ifconfig ethX down command.
+
+Use ethtool to view and set link-down-on-close, as follows::
+
+ ethtool --show-priv-flags ethX
+ ethtool --set-priv-flags ethX link-down-on-close [on|off]
+
+Viewing Link Messages
+---------------------
+Link messages will not be displayed to the console if the distribution is
+restricting system messages. In order to see network driver link messages on
+your console, set dmesg to eight by entering the following::
+
+ dmesg -n 8
+
+NOTE: This setting is not saved across reboots.
+
+Jumbo Frames
+------------
+Jumbo Frames support is enabled by changing the Maximum Transmission Unit (MTU)
+to a value larger than the default value of 1500.
+
+Use the ifconfig command to increase the MTU size. For example, enter the
+following where <x> is the interface number::
+
+ ifconfig eth<x> mtu 9000 up
+
+Alternatively, you can use the ip command as follows::
+
+ ip link set mtu 9000 dev eth<x>
+ ip link set up dev eth<x>
+
+This setting is not saved across reboots. The setting change can be made
+permanent by adding 'MTU=9000' to the file::
+
+ /etc/sysconfig/network-scripts/ifcfg-eth<x> // for RHEL
+ /etc/sysconfig/network/<config_file> // for SLES
+
+NOTE: The maximum MTU setting for Jumbo Frames is 9702. This value coincides
+with the maximum Jumbo Frames size of 9728 bytes.
+
+NOTE: This driver will attempt to use multiple page sized buffers to receive
+each jumbo packet. This should help to avoid buffer starvation issues when
+allocating receive packets.
+
+ethtool
+-------
+The driver utilizes the ethtool interface for driver configuration and
+diagnostics, as well as displaying statistical information. The latest ethtool
+version is required for this functionality. Download it at:
+https://www.kernel.org/pub/software/network/ethtool/
+
+Supported ethtool Commands and Options for Filtering
+----------------------------------------------------
+-n --show-nfc
+ Retrieves the receive network flow classification configurations.
+
+rx-flow-hash tcp4|udp4|ah4|esp4|sctp4|tcp6|udp6|ah6|esp6|sctp6
+ Retrieves the hash options for the specified network traffic type.
+
+-N --config-nfc
+ Configures the receive network flow classification.
+
+rx-flow-hash tcp4|udp4|ah4|esp4|sctp4|tcp6|udp6|ah6|esp6|sctp6 m|v|t|s|d|f|n|r...
+ Configures the hash options for the specified network traffic type.
+
+udp4 UDP over IPv4
+udp6 UDP over IPv6
+
+f Hash on bytes 0 and 1 of the Layer 4 header of the Rx packet.
+n Hash on bytes 2 and 3 of the Layer 4 header of the Rx packet.
+
+Speed and Duplex Configuration
+------------------------------
+In addressing speed and duplex configuration issues, you need to distinguish
+between copper-based adapters and fiber-based adapters.
+
+In the default mode, an Intel(R) Ethernet Network Adapter using copper
+connections will attempt to auto-negotiate with its link partner to determine
+the best setting. If the adapter cannot establish link with the link partner
+using auto-negotiation, you may need to manually configure the adapter and link
+partner to identical settings to establish link and pass packets. This should
+only be needed when attempting to link with an older switch that does not
+support auto-negotiation or one that has been forced to a specific speed or
+duplex mode. Your link partner must match the setting you choose. 1 Gbps speeds
+and higher cannot be forced. Use the autonegotiation advertising setting to
+manually set devices for 1 Gbps and higher.
+
+NOTE: You cannot set the speed for devices based on the Intel(R) Ethernet
+Network Adapter XXV710 based devices.
+
+Speed, duplex, and autonegotiation advertising are configured through the
+ethtool utility.
+
+Caution: Only experienced network administrators should force speed and duplex
+or change autonegotiation advertising manually. The settings at the switch must
+always match the adapter settings. Adapter performance may suffer or your
+adapter may not operate if you configure the adapter differently from your
+switch.
+
+An Intel(R) Ethernet Network Adapter using fiber-based connections, however,
+will not attempt to auto-negotiate with its link partner since those adapters
+operate only in full duplex and only at their native speed.
+
+NAPI
+----
+NAPI (Rx polling mode) is supported in the i40e driver.
+For more information on NAPI, see
+https://wiki.linuxfoundation.org/networking/napi
+
+Flow Control
+------------
+Ethernet Flow Control (IEEE 802.3x) can be configured with ethtool to enable
+receiving and transmitting pause frames for i40e. When transmit is enabled,
+pause frames are generated when the receive packet buffer crosses a predefined
+threshold. When receive is enabled, the transmit unit will halt for the time
+delay specified when a pause frame is received.
+
+NOTE: You must have a flow control capable link partner.
+
+Flow Control is on by default.
+
+Use ethtool to change the flow control settings.
+
+To enable or disable Rx or Tx Flow Control::
+
+ ethtool -A eth? rx <on|off> tx <on|off>
+
+Note: This command only enables or disables Flow Control if auto-negotiation is
+disabled. If auto-negotiation is enabled, this command changes the parameters
+used for auto-negotiation with the link partner.
+
+To enable or disable auto-negotiation::
+
+ ethtool -s eth? autoneg <on|off>
+
+Note: Flow Control auto-negotiation is part of link auto-negotiation. Depending
+on your device, you may not be able to change the auto-negotiation setting.
+
+RSS Hash Flow
+-------------
+Allows you to set the hash bytes per flow type and any combination of one or
+more options for Receive Side Scaling (RSS) hash byte configuration.
+
+::
+
+ # ethtool -N <dev> rx-flow-hash <type> <option>
+
+Where <type> is:
+ tcp4 signifying TCP over IPv4
+ udp4 signifying UDP over IPv4
+ tcp6 signifying TCP over IPv6
+ udp6 signifying UDP over IPv6
+And <option> is one or more of:
+ s Hash on the IP source address of the Rx packet.
+ d Hash on the IP destination address of the Rx packet.
+ f Hash on bytes 0 and 1 of the Layer 4 header of the Rx packet.
+ n Hash on bytes 2 and 3 of the Layer 4 header of the Rx packet.
+
+MAC and VLAN anti-spoofing feature
+----------------------------------
+When a malicious driver attempts to send a spoofed packet, it is dropped by the
+hardware and not transmitted.
+NOTE: This feature can be disabled for a specific Virtual Function (VF)::
+
+ ip link set <pf dev> vf <vf id> spoofchk {off|on}
+
+IEEE 1588 Precision Time Protocol (PTP) Hardware Clock (PHC)
+------------------------------------------------------------
+Precision Time Protocol (PTP) is used to synchronize clocks in a computer
+network. PTP support varies among Intel devices that support this driver. Use
+"ethtool -T <netdev name>" to get a definitive list of PTP capabilities
+supported by the device.
+
+IEEE 802.1ad (QinQ) Support
+---------------------------
+The IEEE 802.1ad standard, informally known as QinQ, allows for multiple VLAN
+IDs within a single Ethernet frame. VLAN IDs are sometimes referred to as
+"tags," and multiple VLAN IDs are thus referred to as a "tag stack." Tag stacks
+allow L2 tunneling and the ability to segregate traffic within a particular
+VLAN ID, among other uses.
+
+The following are examples of how to configure 802.1ad (QinQ)::
+
+ ip link add link eth0 eth0.24 type vlan proto 802.1ad id 24
+ ip link add link eth0.24 eth0.24.371 type vlan proto 802.1Q id 371
+
+Where "24" and "371" are example VLAN IDs.
+
+NOTES:
+ Receive checksum offloads, cloud filters, and VLAN acceleration are not
+ supported for 802.1ad (QinQ) packets.
+
+VXLAN and GENEVE Overlay HW Offloading
+--------------------------------------
+Virtual Extensible LAN (VXLAN) allows you to extend an L2 network over an L3
+network, which may be useful in a virtualized or cloud environment. Some
+Intel(R) Ethernet Network devices perform VXLAN processing, offloading it from
+the operating system. This reduces CPU utilization.
+
+VXLAN offloading is controlled by the Tx and Rx checksum offload options
+provided by ethtool. That is, if Tx checksum offload is enabled, and the
+adapter has the capability, VXLAN offloading is also enabled.
+
+Support for VXLAN and GENEVE HW offloading is dependent on kernel support of
+the HW offloading features.
+
+Multiple Functions per Port
+---------------------------
+Some adapters based on the Intel Ethernet Controller X710/XL710 support
+multiple functions on a single physical port. Configure these functions through
+the System Setup/BIOS.
+
+Minimum TX Bandwidth is the guaranteed minimum data transmission bandwidth, as
+a percentage of the full physical port link speed, that the partition will
+receive. The bandwidth the partition is awarded will never fall below the level
+you specify.
+
+The range for the minimum bandwidth values is:
+1 to ((100 minus # of partitions on the physical port) plus 1)
+For example, if a physical port has 4 partitions, the range would be:
+1 to ((100 - 4) + 1 = 97)
+
+The Maximum Bandwidth percentage represents the maximum transmit bandwidth
+allocated to the partition as a percentage of the full physical port link
+speed. The accepted range of values is 1-100. The value is used as a limiter,
+should you chose that any one particular function not be able to consume 100%
+of a port's bandwidth (should it be available). The sum of all the values for
+Maximum Bandwidth is not restricted, because no more than 100% of a port's
+bandwidth can ever be used.
+
+NOTE: X710/XXV710 devices fail to enable Max VFs (64) when Multiple Functions
+per Port (MFP) and SR-IOV are enabled. An error from i40e is logged that says
+"add vsi failed for VF N, aq_err 16". To workaround the issue, enable less than
+64 virtual functions (VFs).
+
+Data Center Bridging (DCB)
+--------------------------
+DCB is a configuration Quality of Service implementation in hardware. It uses
+the VLAN priority tag (802.1p) to filter traffic. That means that there are 8
+different priorities that traffic can be filtered into. It also enables
+priority flow control (802.1Qbb) which can limit or eliminate the number of
+dropped packets during network stress. Bandwidth can be allocated to each of
+these priorities, which is enforced at the hardware level (802.1Qaz).
+
+Adapter firmware implements LLDP and DCBX protocol agents as per 802.1AB and
+802.1Qaz respectively. The firmware based DCBX agent runs in willing mode only
+and can accept settings from a DCBX capable peer. Software configuration of
+DCBX parameters via dcbtool/lldptool are not supported.
+
+NOTE: Firmware LLDP can be disabled by setting the private flag disable-fw-lldp.
+
+The i40e driver implements the DCB netlink interface layer to allow user-space
+to communicate with the driver and query DCB configuration for the port.
+
+NOTE:
+The kernel assumes that TC0 is available, and will disable Priority Flow
+Control (PFC) on the device if TC0 is not available. To fix this, ensure TC0 is
+enabled when setting up DCB on your switch.
+
+Interrupt Rate Limiting
+-----------------------
+:Valid Range: 0-235 (0=no limit)
+
+The Intel(R) Ethernet Controller XL710 family supports an interrupt rate
+limiting mechanism. The user can control, via ethtool, the number of
+microseconds between interrupts.
+
+Syntax::
+
+ # ethtool -C ethX rx-usecs-high N
+
+The range of 0-235 microseconds provides an effective range of 4,310 to 250,000
+interrupts per second. The value of rx-usecs-high can be set independently of
+rx-usecs and tx-usecs in the same ethtool command, and is also independent of
+the adaptive interrupt moderation algorithm. The underlying hardware supports
+granularity in 4-microsecond intervals, so adjacent values may result in the
+same interrupt rate.
+
+One possible use case is the following::
+
+ # ethtool -C ethX adaptive-rx off adaptive-tx off rx-usecs-high 20 rx-usecs \
+ 5 tx-usecs 5
+
+The above command would disable adaptive interrupt moderation, and allow a
+maximum of 5 microseconds before indicating a receive or transmit was complete.
+However, instead of resulting in as many as 200,000 interrupts per second, it
+limits total interrupts per second to 50,000 via the rx-usecs-high parameter.
+
+Performance Optimization
+========================
+Driver defaults are meant to fit a wide variety of workloads, but if further
+optimization is required we recommend experimenting with the following settings.
+
+NOTE: For better performance when processing small (64B) frame sizes, try
+enabling Hyper threading in the BIOS in order to increase the number of logical
+cores in the system and subsequently increase the number of queues available to
+the adapter.
+
+Virtualized Environments
+------------------------
+1. Disable XPS on both ends by using the included virt_perf_default script
+or by running the following command as root::
+
+ for file in `ls /sys/class/net/<ethX>/queues/tx-*/xps_cpus`;
+ do echo 0 > $file; done
+
+2. Using the appropriate mechanism (vcpupin) in the vm, pin the cpu's to
+individual lcpu's, making sure to use a set of cpu's included in the
+device's local_cpulist: /sys/class/net/<ethX>/device/local_cpulist.
+
+3. Configure as many Rx/Tx queues in the VM as available. Do not rely on
+the default setting of 1.
+
+
+Non-virtualized Environments
+----------------------------
+Pin the adapter's IRQs to specific cores by disabling the irqbalance service
+and using the included set_irq_affinity script. Please see the script's help
+text for further options.
+
+- The following settings will distribute the IRQs across all the cores evenly::
+
+ # scripts/set_irq_affinity -x all <interface1> , [ <interface2>, ... ]
+
+- The following settings will distribute the IRQs across all the cores that are
+ local to the adapter (same NUMA node)::
+
+ # scripts/set_irq_affinity -x local <interface1> ,[ <interface2>, ... ]
+
+For very CPU intensive workloads, we recommend pinning the IRQs to all cores.
+
+For IP Forwarding: Disable Adaptive ITR and lower Rx and Tx interrupts per
+queue using ethtool.
+
+- Setting rx-usecs and tx-usecs to 125 will limit interrupts to about 8000
+ interrupts per second per queue.
+
+::
+
+ # ethtool -C <interface> adaptive-rx off adaptive-tx off rx-usecs 125 \
+ tx-usecs 125
+
+For lower CPU utilization: Disable Adaptive ITR and lower Rx and Tx interrupts
+per queue using ethtool.
+
+- Setting rx-usecs and tx-usecs to 250 will limit interrupts to about 4000
+ interrupts per second per queue.
+
+::
+
+ # ethtool -C <interface> adaptive-rx off adaptive-tx off rx-usecs 250 \
+ tx-usecs 250
+
+For lower latency: Disable Adaptive ITR and ITR by setting Rx and Tx to 0 using
+ethtool.
+
+::
+
+ # ethtool -C <interface> adaptive-rx off adaptive-tx off rx-usecs 0 \
+ tx-usecs 0
+
+Application Device Queues (ADq)
+-------------------------------
+Application Device Queues (ADq) allows you to dedicate one or more queues to a
+specific application. This can reduce latency for the specified application,
+and allow Tx traffic to be rate limited per application. Follow the steps below
+to set ADq.
+
+1. Create traffic classes (TCs). Maximum of 8 TCs can be created per interface.
+The shaper bw_rlimit parameter is optional.
+
+Example: Sets up two tcs, tc0 and tc1, with 16 queues each and max tx rate set
+to 1Gbit for tc0 and 3Gbit for tc1.
+
+::
+
+ # tc qdisc add dev <interface> root mqprio num_tc 2 map 0 0 0 0 1 1 1 1
+ queues 16@0 16@16 hw 1 mode channel shaper bw_rlimit min_rate 1Gbit 2Gbit
+ max_rate 1Gbit 3Gbit
+
+map: priority mapping for up to 16 priorities to tcs (e.g. map 0 0 0 0 1 1 1 1
+sets priorities 0-3 to use tc0 and 4-7 to use tc1)
+
+queues: for each tc, <num queues>@<offset> (e.g. queues 16@0 16@16 assigns
+16 queues to tc0 at offset 0 and 16 queues to tc1 at offset 16. Max total
+number of queues for all tcs is 64 or number of cores, whichever is lower.)
+
+hw 1 mode channel: ‘channel’ with ‘hw’ set to 1 is a new new hardware
+offload mode in mqprio that makes full use of the mqprio options, the
+TCs, the queue configurations, and the QoS parameters.
+
+shaper bw_rlimit: for each tc, sets minimum and maximum bandwidth rates.
+Totals must be equal or less than port speed.
+
+For example: min_rate 1Gbit 3Gbit: Verify bandwidth limit using network
+monitoring tools such as `ifstat` or `sar -n DEV [interval] [number of samples]`
+
+2. Enable HW TC offload on interface::
+
+ # ethtool -K <interface> hw-tc-offload on
+
+3. Apply TCs to ingress (RX) flow of interface::
+
+ # tc qdisc add dev <interface> ingress
+
+NOTES:
+ - Run all tc commands from the iproute2 <pathtoiproute2>/tc/ directory.
+ - ADq is not compatible with cloud filters.
+ - Setting up channels via ethtool (ethtool -L) is not supported when the
+ TCs are configured using mqprio.
+ - You must have iproute2 latest version
+ - NVM version 6.01 or later is required.
+ - ADq cannot be enabled when any the following features are enabled: Data
+ Center Bridging (DCB), Multiple Functions per Port (MFP), or Sideband
+ Filters.
+ - If another driver (for example, DPDK) has set cloud filters, you cannot
+ enable ADq.
+ - Tunnel filters are not supported in ADq. If encapsulated packets do
+ arrive in non-tunnel mode, filtering will be done on the inner headers.
+ For example, for VXLAN traffic in non-tunnel mode, PCTYPE is identified
+ as a VXLAN encapsulated packet, outer headers are ignored. Therefore,
+ inner headers are matched.
+ - If a TC filter on a PF matches traffic over a VF (on the PF), that
+ traffic will be routed to the appropriate queue of the PF, and will
+ not be passed on the VF. Such traffic will end up getting dropped higher
+ up in the TCP/IP stack as it does not match PF address data.
+ - If traffic matches multiple TC filters that point to different TCs,
+ that traffic will be duplicated and sent to all matching TC queues.
+ The hardware switch mirrors the packet to a VSI list when multiple
+ filters are matched.
+
+
+Known Issues/Troubleshooting
+============================
+
+NOTE: 1 Gb devices based on the Intel(R) Ethernet Network Connection X722 do
+not support the following features:
+
+ * Data Center Bridging (DCB)
+ * QOS
+ * VMQ
+ * SR-IOV
+ * Task Encapsulation offload (VXLAN, NVGRE)
+ * Energy Efficient Ethernet (EEE)
+ * Auto-media detect
+
+Unexpected Issues when the device driver and DPDK share a device
+----------------------------------------------------------------
+Unexpected issues may result when an i40e device is in multi driver mode and
+the kernel driver and DPDK driver are sharing the device. This is because
+access to the global NIC resources is not synchronized between multiple
+drivers. Any change to the global NIC configuration (writing to a global
+register, setting global configuration by AQ, or changing switch modes) will
+affect all ports and drivers on the device. Loading DPDK with the
+"multi-driver" module parameter may mitigate some of the issues.
+
+TC0 must be enabled when setting up DCB on a switch
+---------------------------------------------------
+The kernel assumes that TC0 is available, and will disable Priority Flow
+Control (PFC) on the device if TC0 is not available. To fix this, ensure TC0 is
+enabled when setting up DCB on your switch.
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net.