aboutsummaryrefslogtreecommitdiff
path: root/net/rds/ib.c
diff options
context:
space:
mode:
authorLibravatar Linus Torvalds <torvalds@linux-foundation.org>2023-02-21 18:24:12 -0800
committerLibravatar Linus Torvalds <torvalds@linux-foundation.org>2023-02-21 18:24:12 -0800
commit5b7c4cabbb65f5c469464da6c5f614cbd7f730f2 (patch)
treecc5c2d0a898769fd59549594fedb3ee6f84e59a0 /net/rds/ib.c
downloadlinux-5b7c4cabbb65f5c469464da6c5f614cbd7f730f2.tar.gz
linux-5b7c4cabbb65f5c469464da6c5f614cbd7f730f2.zip
Merge tag 'net-next-6.3' of git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net-nextgrafted
Pull networking updates from Jakub Kicinski: "Core: - Add dedicated kmem_cache for typical/small skb->head, avoid having to access struct page at kfree time, and improve memory use. - Introduce sysctl to set default RPS configuration for new netdevs. - Define Netlink protocol specification format which can be used to describe messages used by each family and auto-generate parsers. Add tools for generating kernel data structures and uAPI headers. - Expose all net/core sysctls inside netns. - Remove 4s sleep in netpoll if carrier is instantly detected on boot. - Add configurable limit of MDB entries per port, and port-vlan. - Continue populating drop reasons throughout the stack. - Retire a handful of legacy Qdiscs and classifiers. Protocols: - Support IPv4 big TCP (TSO frames larger than 64kB). - Add IP_LOCAL_PORT_RANGE socket option, to control local port range on socket by socket basis. - Track and report in procfs number of MPTCP sockets used. - Support mixing IPv4 and IPv6 flows in the in-kernel MPTCP path manager. - IPv6: don't check net.ipv6.route.max_size and rely on garbage collection to free memory (similarly to IPv4). - Support Penultimate Segment Pop (PSP) flavor in SRv6 (RFC8986). - ICMP: add per-rate limit counters. - Add support for user scanning requests in ieee802154. - Remove static WEP support. - Support minimal Wi-Fi 7 Extremely High Throughput (EHT) rate reporting. - WiFi 7 EHT channel puncturing support (client & AP). BPF: - Add a rbtree data structure following the "next-gen data structure" precedent set by recently added linked list, that is, by using kfunc + kptr instead of adding a new BPF map type. - Expose XDP hints via kfuncs with initial support for RX hash and timestamp metadata. - Add BPF_F_NO_TUNNEL_KEY extension to bpf_skb_set_tunnel_key to better support decap on GRE tunnel devices not operating in collect metadata. - Improve x86 JIT's codegen for PROBE_MEM runtime error checks. - Remove the need for trace_printk_lock for bpf_trace_printk and bpf_trace_vprintk helpers. - Extend libbpf's bpf_tracing.h support for tracing arguments of kprobes/uprobes and syscall as a special case. - Significantly reduce the search time for module symbols by livepatch and BPF. - Enable cpumasks to be used as kptrs, which is useful for tracing programs tracking which tasks end up running on which CPUs in different time intervals. - Add support for BPF trampoline on s390x and riscv64. - Add capability to export the XDP features supported by the NIC. - Add __bpf_kfunc tag for marking kernel functions as kfuncs. - Add cgroup.memory=nobpf kernel parameter option to disable BPF memory accounting for container environments. Netfilter: - Remove the CLUSTERIP target. It has been marked as obsolete for years, and we still have WARN splats wrt races of the out-of-band /proc interface installed by this target. - Add 'destroy' commands to nf_tables. They are identical to the existing 'delete' commands, but do not return an error if the referenced object (set, chain, rule...) did not exist. Driver API: - Improve cpumask_local_spread() locality to help NICs set the right IRQ affinity on AMD platforms. - Separate C22 and C45 MDIO bus transactions more clearly. - Introduce new DCB table to control DSCP rewrite on egress. - Support configuration of Physical Layer Collision Avoidance (PLCA) Reconciliation Sublayer (RS) (802.3cg-2019). Modern version of shared medium Ethernet. - Support for MAC Merge layer (IEEE 802.3-2018 clause 99). Allowing preemption of low priority frames by high priority frames. - Add support for controlling MACSec offload using netlink SET. - Rework devlink instance refcounts to allow registration and de-registration under the instance lock. Split the code into multiple files, drop some of the unnecessarily granular locks and factor out common parts of netlink operation handling. - Add TX frame aggregation parameters (for USB drivers). - Add a new attr TCA_EXT_WARN_MSG to report TC (offload) warning messages with notifications for debug. - Allow offloading of UDP NEW connections via act_ct. - Add support for per action HW stats in TC. - Support hardware miss to TC action (continue processing in SW from a specific point in the action chain). - Warn if old Wireless Extension user space interface is used with modern cfg80211/mac80211 drivers. Do not support Wireless Extensions for Wi-Fi 7 devices at all. Everyone should switch to using nl80211 interface instead. - Improve the CAN bit timing configuration. Use extack to return error messages directly to user space, update the SJW handling, including the definition of a new default value that will benefit CAN-FD controllers, by increasing their oscillator tolerance. New hardware / drivers: - Ethernet: - nVidia BlueField-3 support (control traffic driver) - Ethernet support for imx93 SoCs - Motorcomm yt8531 gigabit Ethernet PHY - onsemi NCN26000 10BASE-T1S PHY (with support for PLCA) - Microchip LAN8841 PHY (incl. cable diagnostics and PTP) - Amlogic gxl MDIO mux - WiFi: - RealTek RTL8188EU (rtl8xxxu) - Qualcomm Wi-Fi 7 devices (ath12k) - CAN: - Renesas R-Car V4H Drivers: - Bluetooth: - Set Per Platform Antenna Gain (PPAG) for Intel controllers. - Ethernet NICs: - Intel (1G, igc): - support TSN / Qbv / packet scheduling features of i226 model - Intel (100G, ice): - use GNSS subsystem instead of TTY - multi-buffer XDP support - extend support for GPIO pins to E823 devices - nVidia/Mellanox: - update the shared buffer configuration on PFC commands - implement PTP adjphase function for HW offset control - TC support for Geneve and GRE with VF tunnel offload - more efficient crypto key management method - multi-port eswitch support - Netronome/Corigine: - add DCB IEEE support - support IPsec offloading for NFP3800 - Freescale/NXP (enetc): - support XDP_REDIRECT for XDP non-linear buffers - improve reconfig, avoid link flap and waiting for idle - support MAC Merge layer - Other NICs: - sfc/ef100: add basic devlink support for ef100 - ionic: rx_push mode operation (writing descriptors via MMIO) - bnxt: use the auxiliary bus abstraction for RDMA - r8169: disable ASPM and reset bus in case of tx timeout - cpsw: support QSGMII mode for J721e CPSW9G - cpts: support pulse-per-second output - ngbe: add an mdio bus driver - usbnet: optimize usbnet_bh() by avoiding unnecessary queuing - r8152: handle devices with FW with NCM support - amd-xgbe: support 10Mbps, 2.5GbE speeds and rx-adaptation - virtio-net: support multi buffer XDP - virtio/vsock: replace virtio_vsock_pkt with sk_buff - tsnep: XDP support - Ethernet high-speed switches: - nVidia/Mellanox (mlxsw): - add support for latency TLV (in FW control messages) - Microchip (sparx5): - separate explicit and implicit traffic forwarding rules, make the implicit rules always active - add support for egress DSCP rewrite - IS0 VCAP support (Ingress Classification) - IS2 VCAP filters (protos, L3 addrs, L4 ports, flags, ToS etc.) - ES2 VCAP support (Egress Access Control) - support for Per-Stream Filtering and Policing (802.1Q, 8.6.5.1) - Ethernet embedded switches: - Marvell (mv88e6xxx): - add MAB (port auth) offload support - enable PTP receive for mv88e6390 - NXP (ocelot): - support MAC Merge layer - support for the the vsc7512 internal copper phys - Microchip: - lan9303: convert to PHYLINK - lan966x: support TC flower filter statistics - lan937x: PTP support for KSZ9563/KSZ8563 and LAN937x - lan937x: support Credit Based Shaper configuration - ksz9477: support Energy Efficient Ethernet - other: - qca8k: convert to regmap read/write API, use bulk operations - rswitch: Improve TX timestamp accuracy - Intel WiFi (iwlwifi): - EHT (Wi-Fi 7) rate reporting - STEP equalizer support: transfer some STEP (connection to radio on platforms with integrated wifi) related parameters from the BIOS to the firmware. - Qualcomm 802.11ax WiFi (ath11k): - IPQ5018 support - Fine Timing Measurement (FTM) responder role support - channel 177 support - MediaTek WiFi (mt76): - per-PHY LED support - mt7996: EHT (Wi-Fi 7) support - Wireless Ethernet Dispatch (WED) reset support - switch to using page pool allocator - RealTek WiFi (rtw89): - support new version of Bluetooth co-existance - Mobile: - rmnet: support TX aggregation" * tag 'net-next-6.3' of git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net-next: (1872 commits) page_pool: add a comment explaining the fragment counter usage net: ethtool: fix __ethtool_dev_mm_supported() implementation ethtool: pse-pd: Fix double word in comments xsk: add linux/vmalloc.h to xsk.c sefltests: netdevsim: wait for devlink instance after netns removal selftest: fib_tests: Always cleanup before exit net/mlx5e: Align IPsec ASO result memory to be as required by hardware net/mlx5e: TC, Set CT miss to the specific ct action instance net/mlx5e: Rename CHAIN_TO_REG to MAPPED_OBJ_TO_REG net/mlx5: Refactor tc miss handling to a single function net/mlx5: Kconfig: Make tc offload depend on tc skb extension net/sched: flower: Support hardware miss to tc action net/sched: flower: Move filter handle initialization earlier net/sched: cls_api: Support hardware miss to tc action net/sched: Rename user cookie and act cookie sfc: fix builds without CONFIG_RTC_LIB sfc: clean up some inconsistent indentings net/mlx4_en: Introduce flexible array to silence overflow warning net: lan966x: Fix possible deadlock inside PTP net/ulp: Remove redundant ->clone() test in inet_clone_ulp(). ...
Diffstat (limited to 'net/rds/ib.c')
-rw-r--r--net/rds/ib.c607
1 files changed, 607 insertions, 0 deletions
diff --git a/net/rds/ib.c b/net/rds/ib.c
new file mode 100644
index 000000000..9826fe7f9
--- /dev/null
+++ b/net/rds/ib.c
@@ -0,0 +1,607 @@
+/*
+ * Copyright (c) 2006, 2019 Oracle and/or its affiliates. All rights reserved.
+ *
+ * This software is available to you under a choice of one of two
+ * licenses. You may choose to be licensed under the terms of the GNU
+ * General Public License (GPL) Version 2, available from the file
+ * COPYING in the main directory of this source tree, or the
+ * OpenIB.org BSD license below:
+ *
+ * Redistribution and use in source and binary forms, with or
+ * without modification, are permitted provided that the following
+ * conditions are met:
+ *
+ * - Redistributions of source code must retain the above
+ * copyright notice, this list of conditions and the following
+ * disclaimer.
+ *
+ * - Redistributions in binary form must reproduce the above
+ * copyright notice, this list of conditions and the following
+ * disclaimer in the documentation and/or other materials
+ * provided with the distribution.
+ *
+ * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
+ * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
+ * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
+ * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS
+ * BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN
+ * ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN
+ * CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
+ * SOFTWARE.
+ *
+ */
+#include <linux/kernel.h>
+#include <linux/in.h>
+#include <linux/if.h>
+#include <linux/netdevice.h>
+#include <linux/inetdevice.h>
+#include <linux/if_arp.h>
+#include <linux/delay.h>
+#include <linux/slab.h>
+#include <linux/module.h>
+#include <net/addrconf.h>
+
+#include "rds_single_path.h"
+#include "rds.h"
+#include "ib.h"
+#include "ib_mr.h"
+
+static unsigned int rds_ib_mr_1m_pool_size = RDS_MR_1M_POOL_SIZE;
+static unsigned int rds_ib_mr_8k_pool_size = RDS_MR_8K_POOL_SIZE;
+unsigned int rds_ib_retry_count = RDS_IB_DEFAULT_RETRY_COUNT;
+static atomic_t rds_ib_unloading;
+
+module_param(rds_ib_mr_1m_pool_size, int, 0444);
+MODULE_PARM_DESC(rds_ib_mr_1m_pool_size, " Max number of 1M mr per HCA");
+module_param(rds_ib_mr_8k_pool_size, int, 0444);
+MODULE_PARM_DESC(rds_ib_mr_8k_pool_size, " Max number of 8K mr per HCA");
+module_param(rds_ib_retry_count, int, 0444);
+MODULE_PARM_DESC(rds_ib_retry_count, " Number of hw retries before reporting an error");
+
+/*
+ * we have a clumsy combination of RCU and a rwsem protecting this list
+ * because it is used both in the get_mr fast path and while blocking in
+ * the FMR flushing path.
+ */
+DECLARE_RWSEM(rds_ib_devices_lock);
+struct list_head rds_ib_devices;
+
+/* NOTE: if also grabbing ibdev lock, grab this first */
+DEFINE_SPINLOCK(ib_nodev_conns_lock);
+LIST_HEAD(ib_nodev_conns);
+
+static void rds_ib_nodev_connect(void)
+{
+ struct rds_ib_connection *ic;
+
+ spin_lock(&ib_nodev_conns_lock);
+ list_for_each_entry(ic, &ib_nodev_conns, ib_node)
+ rds_conn_connect_if_down(ic->conn);
+ spin_unlock(&ib_nodev_conns_lock);
+}
+
+static void rds_ib_dev_shutdown(struct rds_ib_device *rds_ibdev)
+{
+ struct rds_ib_connection *ic;
+ unsigned long flags;
+
+ spin_lock_irqsave(&rds_ibdev->spinlock, flags);
+ list_for_each_entry(ic, &rds_ibdev->conn_list, ib_node)
+ rds_conn_path_drop(&ic->conn->c_path[0], true);
+ spin_unlock_irqrestore(&rds_ibdev->spinlock, flags);
+}
+
+/*
+ * rds_ib_destroy_mr_pool() blocks on a few things and mrs drop references
+ * from interrupt context so we push freing off into a work struct in krdsd.
+ */
+static void rds_ib_dev_free(struct work_struct *work)
+{
+ struct rds_ib_ipaddr *i_ipaddr, *i_next;
+ struct rds_ib_device *rds_ibdev = container_of(work,
+ struct rds_ib_device, free_work);
+
+ if (rds_ibdev->mr_8k_pool)
+ rds_ib_destroy_mr_pool(rds_ibdev->mr_8k_pool);
+ if (rds_ibdev->mr_1m_pool)
+ rds_ib_destroy_mr_pool(rds_ibdev->mr_1m_pool);
+ if (rds_ibdev->pd)
+ ib_dealloc_pd(rds_ibdev->pd);
+
+ list_for_each_entry_safe(i_ipaddr, i_next, &rds_ibdev->ipaddr_list, list) {
+ list_del(&i_ipaddr->list);
+ kfree(i_ipaddr);
+ }
+
+ kfree(rds_ibdev->vector_load);
+
+ kfree(rds_ibdev);
+}
+
+void rds_ib_dev_put(struct rds_ib_device *rds_ibdev)
+{
+ BUG_ON(refcount_read(&rds_ibdev->refcount) == 0);
+ if (refcount_dec_and_test(&rds_ibdev->refcount))
+ queue_work(rds_wq, &rds_ibdev->free_work);
+}
+
+static int rds_ib_add_one(struct ib_device *device)
+{
+ struct rds_ib_device *rds_ibdev;
+ int ret;
+
+ /* Only handle IB (no iWARP) devices */
+ if (device->node_type != RDMA_NODE_IB_CA)
+ return -EOPNOTSUPP;
+
+ /* Device must support FRWR */
+ if (!(device->attrs.device_cap_flags & IB_DEVICE_MEM_MGT_EXTENSIONS))
+ return -EOPNOTSUPP;
+
+ rds_ibdev = kzalloc_node(sizeof(struct rds_ib_device), GFP_KERNEL,
+ ibdev_to_node(device));
+ if (!rds_ibdev)
+ return -ENOMEM;
+
+ spin_lock_init(&rds_ibdev->spinlock);
+ refcount_set(&rds_ibdev->refcount, 1);
+ INIT_WORK(&rds_ibdev->free_work, rds_ib_dev_free);
+
+ INIT_LIST_HEAD(&rds_ibdev->ipaddr_list);
+ INIT_LIST_HEAD(&rds_ibdev->conn_list);
+
+ rds_ibdev->max_wrs = device->attrs.max_qp_wr;
+ rds_ibdev->max_sge = min(device->attrs.max_send_sge, RDS_IB_MAX_SGE);
+
+ rds_ibdev->odp_capable =
+ !!(device->attrs.kernel_cap_flags &
+ IBK_ON_DEMAND_PAGING) &&
+ !!(device->attrs.odp_caps.per_transport_caps.rc_odp_caps &
+ IB_ODP_SUPPORT_WRITE) &&
+ !!(device->attrs.odp_caps.per_transport_caps.rc_odp_caps &
+ IB_ODP_SUPPORT_READ);
+
+ rds_ibdev->max_1m_mrs = device->attrs.max_mr ?
+ min_t(unsigned int, (device->attrs.max_mr / 2),
+ rds_ib_mr_1m_pool_size) : rds_ib_mr_1m_pool_size;
+
+ rds_ibdev->max_8k_mrs = device->attrs.max_mr ?
+ min_t(unsigned int, ((device->attrs.max_mr / 2) * RDS_MR_8K_SCALE),
+ rds_ib_mr_8k_pool_size) : rds_ib_mr_8k_pool_size;
+
+ rds_ibdev->max_initiator_depth = device->attrs.max_qp_init_rd_atom;
+ rds_ibdev->max_responder_resources = device->attrs.max_qp_rd_atom;
+
+ rds_ibdev->vector_load = kcalloc(device->num_comp_vectors,
+ sizeof(int),
+ GFP_KERNEL);
+ if (!rds_ibdev->vector_load) {
+ pr_err("RDS/IB: %s failed to allocate vector memory\n",
+ __func__);
+ ret = -ENOMEM;
+ goto put_dev;
+ }
+
+ rds_ibdev->dev = device;
+ rds_ibdev->pd = ib_alloc_pd(device, 0);
+ if (IS_ERR(rds_ibdev->pd)) {
+ ret = PTR_ERR(rds_ibdev->pd);
+ rds_ibdev->pd = NULL;
+ goto put_dev;
+ }
+
+ rds_ibdev->mr_1m_pool =
+ rds_ib_create_mr_pool(rds_ibdev, RDS_IB_MR_1M_POOL);
+ if (IS_ERR(rds_ibdev->mr_1m_pool)) {
+ ret = PTR_ERR(rds_ibdev->mr_1m_pool);
+ rds_ibdev->mr_1m_pool = NULL;
+ goto put_dev;
+ }
+
+ rds_ibdev->mr_8k_pool =
+ rds_ib_create_mr_pool(rds_ibdev, RDS_IB_MR_8K_POOL);
+ if (IS_ERR(rds_ibdev->mr_8k_pool)) {
+ ret = PTR_ERR(rds_ibdev->mr_8k_pool);
+ rds_ibdev->mr_8k_pool = NULL;
+ goto put_dev;
+ }
+
+ rdsdebug("RDS/IB: max_mr = %d, max_wrs = %d, max_sge = %d, max_1m_mrs = %d, max_8k_mrs = %d\n",
+ device->attrs.max_mr, rds_ibdev->max_wrs, rds_ibdev->max_sge,
+ rds_ibdev->max_1m_mrs, rds_ibdev->max_8k_mrs);
+
+ pr_info("RDS/IB: %s: added\n", device->name);
+
+ down_write(&rds_ib_devices_lock);
+ list_add_tail_rcu(&rds_ibdev->list, &rds_ib_devices);
+ up_write(&rds_ib_devices_lock);
+ refcount_inc(&rds_ibdev->refcount);
+
+ ib_set_client_data(device, &rds_ib_client, rds_ibdev);
+
+ rds_ib_nodev_connect();
+ return 0;
+
+put_dev:
+ rds_ib_dev_put(rds_ibdev);
+ return ret;
+}
+
+/*
+ * New connections use this to find the device to associate with the
+ * connection. It's not in the fast path so we're not concerned about the
+ * performance of the IB call. (As of this writing, it uses an interrupt
+ * blocking spinlock to serialize walking a per-device list of all registered
+ * clients.)
+ *
+ * RCU is used to handle incoming connections racing with device teardown.
+ * Rather than use a lock to serialize removal from the client_data and
+ * getting a new reference, we use an RCU grace period. The destruction
+ * path removes the device from client_data and then waits for all RCU
+ * readers to finish.
+ *
+ * A new connection can get NULL from this if its arriving on a
+ * device that is in the process of being removed.
+ */
+struct rds_ib_device *rds_ib_get_client_data(struct ib_device *device)
+{
+ struct rds_ib_device *rds_ibdev;
+
+ rcu_read_lock();
+ rds_ibdev = ib_get_client_data(device, &rds_ib_client);
+ if (rds_ibdev)
+ refcount_inc(&rds_ibdev->refcount);
+ rcu_read_unlock();
+ return rds_ibdev;
+}
+
+/*
+ * The IB stack is letting us know that a device is going away. This can
+ * happen if the underlying HCA driver is removed or if PCI hotplug is removing
+ * the pci function, for example.
+ *
+ * This can be called at any time and can be racing with any other RDS path.
+ */
+static void rds_ib_remove_one(struct ib_device *device, void *client_data)
+{
+ struct rds_ib_device *rds_ibdev = client_data;
+
+ rds_ib_dev_shutdown(rds_ibdev);
+
+ /* stop connection attempts from getting a reference to this device. */
+ ib_set_client_data(device, &rds_ib_client, NULL);
+
+ down_write(&rds_ib_devices_lock);
+ list_del_rcu(&rds_ibdev->list);
+ up_write(&rds_ib_devices_lock);
+
+ /*
+ * This synchronize rcu is waiting for readers of both the ib
+ * client data and the devices list to finish before we drop
+ * both of those references.
+ */
+ synchronize_rcu();
+ rds_ib_dev_put(rds_ibdev);
+ rds_ib_dev_put(rds_ibdev);
+}
+
+struct ib_client rds_ib_client = {
+ .name = "rds_ib",
+ .add = rds_ib_add_one,
+ .remove = rds_ib_remove_one
+};
+
+static int rds_ib_conn_info_visitor(struct rds_connection *conn,
+ void *buffer)
+{
+ struct rds_info_rdma_connection *iinfo = buffer;
+ struct rds_ib_connection *ic = conn->c_transport_data;
+
+ /* We will only ever look at IB transports */
+ if (conn->c_trans != &rds_ib_transport)
+ return 0;
+ if (conn->c_isv6)
+ return 0;
+
+ iinfo->src_addr = conn->c_laddr.s6_addr32[3];
+ iinfo->dst_addr = conn->c_faddr.s6_addr32[3];
+ if (ic) {
+ iinfo->tos = conn->c_tos;
+ iinfo->sl = ic->i_sl;
+ }
+
+ memset(&iinfo->src_gid, 0, sizeof(iinfo->src_gid));
+ memset(&iinfo->dst_gid, 0, sizeof(iinfo->dst_gid));
+ if (rds_conn_state(conn) == RDS_CONN_UP) {
+ struct rds_ib_device *rds_ibdev;
+
+ rdma_read_gids(ic->i_cm_id, (union ib_gid *)&iinfo->src_gid,
+ (union ib_gid *)&iinfo->dst_gid);
+
+ rds_ibdev = ic->rds_ibdev;
+ iinfo->max_send_wr = ic->i_send_ring.w_nr;
+ iinfo->max_recv_wr = ic->i_recv_ring.w_nr;
+ iinfo->max_send_sge = rds_ibdev->max_sge;
+ rds_ib_get_mr_info(rds_ibdev, iinfo);
+ iinfo->cache_allocs = atomic_read(&ic->i_cache_allocs);
+ }
+ return 1;
+}
+
+#if IS_ENABLED(CONFIG_IPV6)
+/* IPv6 version of rds_ib_conn_info_visitor(). */
+static int rds6_ib_conn_info_visitor(struct rds_connection *conn,
+ void *buffer)
+{
+ struct rds6_info_rdma_connection *iinfo6 = buffer;
+ struct rds_ib_connection *ic = conn->c_transport_data;
+
+ /* We will only ever look at IB transports */
+ if (conn->c_trans != &rds_ib_transport)
+ return 0;
+
+ iinfo6->src_addr = conn->c_laddr;
+ iinfo6->dst_addr = conn->c_faddr;
+ if (ic) {
+ iinfo6->tos = conn->c_tos;
+ iinfo6->sl = ic->i_sl;
+ }
+
+ memset(&iinfo6->src_gid, 0, sizeof(iinfo6->src_gid));
+ memset(&iinfo6->dst_gid, 0, sizeof(iinfo6->dst_gid));
+
+ if (rds_conn_state(conn) == RDS_CONN_UP) {
+ struct rds_ib_device *rds_ibdev;
+
+ rdma_read_gids(ic->i_cm_id, (union ib_gid *)&iinfo6->src_gid,
+ (union ib_gid *)&iinfo6->dst_gid);
+ rds_ibdev = ic->rds_ibdev;
+ iinfo6->max_send_wr = ic->i_send_ring.w_nr;
+ iinfo6->max_recv_wr = ic->i_recv_ring.w_nr;
+ iinfo6->max_send_sge = rds_ibdev->max_sge;
+ rds6_ib_get_mr_info(rds_ibdev, iinfo6);
+ iinfo6->cache_allocs = atomic_read(&ic->i_cache_allocs);
+ }
+ return 1;
+}
+#endif
+
+static void rds_ib_ic_info(struct socket *sock, unsigned int len,
+ struct rds_info_iterator *iter,
+ struct rds_info_lengths *lens)
+{
+ u64 buffer[(sizeof(struct rds_info_rdma_connection) + 7) / 8];
+
+ rds_for_each_conn_info(sock, len, iter, lens,
+ rds_ib_conn_info_visitor,
+ buffer,
+ sizeof(struct rds_info_rdma_connection));
+}
+
+#if IS_ENABLED(CONFIG_IPV6)
+/* IPv6 version of rds_ib_ic_info(). */
+static void rds6_ib_ic_info(struct socket *sock, unsigned int len,
+ struct rds_info_iterator *iter,
+ struct rds_info_lengths *lens)
+{
+ u64 buffer[(sizeof(struct rds6_info_rdma_connection) + 7) / 8];
+
+ rds_for_each_conn_info(sock, len, iter, lens,
+ rds6_ib_conn_info_visitor,
+ buffer,
+ sizeof(struct rds6_info_rdma_connection));
+}
+#endif
+
+/*
+ * Early RDS/IB was built to only bind to an address if there is an IPoIB
+ * device with that address set.
+ *
+ * If it were me, I'd advocate for something more flexible. Sending and
+ * receiving should be device-agnostic. Transports would try and maintain
+ * connections between peers who have messages queued. Userspace would be
+ * allowed to influence which paths have priority. We could call userspace
+ * asserting this policy "routing".
+ */
+static int rds_ib_laddr_check(struct net *net, const struct in6_addr *addr,
+ __u32 scope_id)
+{
+ int ret;
+ struct rdma_cm_id *cm_id;
+#if IS_ENABLED(CONFIG_IPV6)
+ struct sockaddr_in6 sin6;
+#endif
+ struct sockaddr_in sin;
+ struct sockaddr *sa;
+ bool isv4;
+
+ isv4 = ipv6_addr_v4mapped(addr);
+ /* Create a CMA ID and try to bind it. This catches both
+ * IB and iWARP capable NICs.
+ */
+ cm_id = rdma_create_id(&init_net, rds_rdma_cm_event_handler,
+ NULL, RDMA_PS_TCP, IB_QPT_RC);
+ if (IS_ERR(cm_id))
+ return PTR_ERR(cm_id);
+
+ if (isv4) {
+ memset(&sin, 0, sizeof(sin));
+ sin.sin_family = AF_INET;
+ sin.sin_addr.s_addr = addr->s6_addr32[3];
+ sa = (struct sockaddr *)&sin;
+ } else {
+#if IS_ENABLED(CONFIG_IPV6)
+ memset(&sin6, 0, sizeof(sin6));
+ sin6.sin6_family = AF_INET6;
+ sin6.sin6_addr = *addr;
+ sin6.sin6_scope_id = scope_id;
+ sa = (struct sockaddr *)&sin6;
+
+ /* XXX Do a special IPv6 link local address check here. The
+ * reason is that rdma_bind_addr() always succeeds with IPv6
+ * link local address regardless it is indeed configured in a
+ * system.
+ */
+ if (ipv6_addr_type(addr) & IPV6_ADDR_LINKLOCAL) {
+ struct net_device *dev;
+
+ if (scope_id == 0) {
+ ret = -EADDRNOTAVAIL;
+ goto out;
+ }
+
+ /* Use init_net for now as RDS is not network
+ * name space aware.
+ */
+ dev = dev_get_by_index(&init_net, scope_id);
+ if (!dev) {
+ ret = -EADDRNOTAVAIL;
+ goto out;
+ }
+ if (!ipv6_chk_addr(&init_net, addr, dev, 1)) {
+ dev_put(dev);
+ ret = -EADDRNOTAVAIL;
+ goto out;
+ }
+ dev_put(dev);
+ }
+#else
+ ret = -EADDRNOTAVAIL;
+ goto out;
+#endif
+ }
+
+ /* rdma_bind_addr will only succeed for IB & iWARP devices */
+ ret = rdma_bind_addr(cm_id, sa);
+ /* due to this, we will claim to support iWARP devices unless we
+ check node_type. */
+ if (ret || !cm_id->device ||
+ cm_id->device->node_type != RDMA_NODE_IB_CA)
+ ret = -EADDRNOTAVAIL;
+
+ rdsdebug("addr %pI6c%%%u ret %d node type %d\n",
+ addr, scope_id, ret,
+ cm_id->device ? cm_id->device->node_type : -1);
+
+out:
+ rdma_destroy_id(cm_id);
+
+ return ret;
+}
+
+static void rds_ib_unregister_client(void)
+{
+ ib_unregister_client(&rds_ib_client);
+ /* wait for rds_ib_dev_free() to complete */
+ flush_workqueue(rds_wq);
+}
+
+static void rds_ib_set_unloading(void)
+{
+ atomic_set(&rds_ib_unloading, 1);
+}
+
+static bool rds_ib_is_unloading(struct rds_connection *conn)
+{
+ struct rds_conn_path *cp = &conn->c_path[0];
+
+ return (test_bit(RDS_DESTROY_PENDING, &cp->cp_flags) ||
+ atomic_read(&rds_ib_unloading) != 0);
+}
+
+void rds_ib_exit(void)
+{
+ rds_ib_set_unloading();
+ synchronize_rcu();
+ rds_info_deregister_func(RDS_INFO_IB_CONNECTIONS, rds_ib_ic_info);
+#if IS_ENABLED(CONFIG_IPV6)
+ rds_info_deregister_func(RDS6_INFO_IB_CONNECTIONS, rds6_ib_ic_info);
+#endif
+ rds_ib_unregister_client();
+ rds_ib_destroy_nodev_conns();
+ rds_ib_sysctl_exit();
+ rds_ib_recv_exit();
+ rds_trans_unregister(&rds_ib_transport);
+ rds_ib_mr_exit();
+}
+
+static u8 rds_ib_get_tos_map(u8 tos)
+{
+ /* 1:1 user to transport map for RDMA transport.
+ * In future, if custom map is desired, hook can export
+ * user configurable map.
+ */
+ return tos;
+}
+
+struct rds_transport rds_ib_transport = {
+ .laddr_check = rds_ib_laddr_check,
+ .xmit_path_complete = rds_ib_xmit_path_complete,
+ .xmit = rds_ib_xmit,
+ .xmit_rdma = rds_ib_xmit_rdma,
+ .xmit_atomic = rds_ib_xmit_atomic,
+ .recv_path = rds_ib_recv_path,
+ .conn_alloc = rds_ib_conn_alloc,
+ .conn_free = rds_ib_conn_free,
+ .conn_path_connect = rds_ib_conn_path_connect,
+ .conn_path_shutdown = rds_ib_conn_path_shutdown,
+ .inc_copy_to_user = rds_ib_inc_copy_to_user,
+ .inc_free = rds_ib_inc_free,
+ .cm_initiate_connect = rds_ib_cm_initiate_connect,
+ .cm_handle_connect = rds_ib_cm_handle_connect,
+ .cm_connect_complete = rds_ib_cm_connect_complete,
+ .stats_info_copy = rds_ib_stats_info_copy,
+ .exit = rds_ib_exit,
+ .get_mr = rds_ib_get_mr,
+ .sync_mr = rds_ib_sync_mr,
+ .free_mr = rds_ib_free_mr,
+ .flush_mrs = rds_ib_flush_mrs,
+ .get_tos_map = rds_ib_get_tos_map,
+ .t_owner = THIS_MODULE,
+ .t_name = "infiniband",
+ .t_unloading = rds_ib_is_unloading,
+ .t_type = RDS_TRANS_IB
+};
+
+int rds_ib_init(void)
+{
+ int ret;
+
+ INIT_LIST_HEAD(&rds_ib_devices);
+
+ ret = rds_ib_mr_init();
+ if (ret)
+ goto out;
+
+ ret = ib_register_client(&rds_ib_client);
+ if (ret)
+ goto out_mr_exit;
+
+ ret = rds_ib_sysctl_init();
+ if (ret)
+ goto out_ibreg;
+
+ ret = rds_ib_recv_init();
+ if (ret)
+ goto out_sysctl;
+
+ rds_trans_register(&rds_ib_transport);
+
+ rds_info_register_func(RDS_INFO_IB_CONNECTIONS, rds_ib_ic_info);
+#if IS_ENABLED(CONFIG_IPV6)
+ rds_info_register_func(RDS6_INFO_IB_CONNECTIONS, rds6_ib_ic_info);
+#endif
+
+ goto out;
+
+out_sysctl:
+ rds_ib_sysctl_exit();
+out_ibreg:
+ rds_ib_unregister_client();
+out_mr_exit:
+ rds_ib_mr_exit();
+out:
+ return ret;
+}
+
+MODULE_LICENSE("GPL");